完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLee, Yuan-Geuyen_US
dc.contributor.authorWu, Hung-Yien_US
dc.contributor.authorHsu, Chuan-Liangen_US
dc.contributor.authorLiang, Hong-Jenen_US
dc.contributor.authorYuan, Chiun-Jyeen_US
dc.contributor.authorJang, Hung-Deren_US
dc.date.accessioned2014-12-08T15:08:44Z-
dc.date.available2014-12-08T15:08:44Z-
dc.date.issued2009-09-07en_US
dc.identifier.issn0925-4005en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.snb.2009.06.028en_US
dc.identifier.urihttp://hdl.handle.net/11536/6686-
dc.description.abstractA novel method for monitoring the growth of coliforms in milk was developed based on measuring the current change in an amperometric sensor. The sensor consists of a circuit with a homemade potentiostat and a pair of electrodes. The electrode was immersed in milk samples containing methylene blue with various concentrations of bacterial inoculums. The microbial metabolism led to the reduction of methylene blue resulting in a change of current. The time required to identify readily detectable change (detection time, DT) provided an approximate measurement of the amount of microorganisms in the initial inoculums. The sensor system used in this study has the selectivity towards coliform bacteria such as Escherichia coli and Enterobacter aerogenes. The calibration curve of DT against concentration of coliform showed a linear correlation coefficient (R(2) = 0.9192) over the range of 10(2)-10(8) CFU/mL. The sensor was able to detect the coliform bacteria at initial concentrations of 10(5) CFU/mL within 6 h, making it suitable for use in real-time monitoring of bacterial growth. This system has potential application in the detection of coliform concentration in milk at dairy farms when a proper selective media is designed. (C) 2009 Elsevier B.V. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectAmperometric sensoren_US
dc.subjectMethylene blueen_US
dc.subjectColiformsen_US
dc.subjectDetection timeen_US
dc.titleA rapid and selective method for monitoring the growth of coliforms in milk using the combination of amperometric sensor and reducing of methylene blueen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.snb.2009.06.028en_US
dc.identifier.journalSENSORS AND ACTUATORS B-CHEMICALen_US
dc.citation.volume141en_US
dc.citation.issue2en_US
dc.citation.spage575en_US
dc.citation.epage580en_US
dc.contributor.department生物科技學系zh_TW
dc.contributor.departmentDepartment of Biological Science and Technologyen_US
dc.identifier.wosnumberWOS:000270343000034-
dc.citation.woscount2-
顯示於類別:期刊論文


文件中的檔案:

  1. 000270343000034.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。