完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Tseng, P. C. | en_US |
dc.contributor.author | Chu, H. S. | en_US |
dc.date.accessioned | 2014-12-08T15:09:21Z | - |
dc.date.available | 2014-12-08T15:09:21Z | - |
dc.date.issued | 2009-06-01 | en_US |
dc.identifier.issn | 0017-9310 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.ijheatmasstransfer.2009.01.033 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/7143 | - |
dc.description.abstract | The effects of adding polyethylene (PE) in polystyrene (PS) foaming material on the cell structure and the heat transfer of vacuum insulation panels (VIPs) are examined in this study. Several parameters are proposed to describe the foam structure, namely, the broken cell ratio, the average cell size and the solid volume fraction. Adding 2% PE was effective in altering the cell structure and reducing the heat transfer, while adding 5% PE did not improve the performance further. The lowest thermal conductivity found in this study is 4.4 mW m(-1) K(-1), which is among the best published performances of VIP. (C) 2009 Elsevier Ltd. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Broken cell ratio | en_US |
dc.subject | PS foam insulation | en_US |
dc.subject | Solid volume fraction | en_US |
dc.title | The effects of PE additive on the performance of polystyrene vacuum insulation panels | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.ijheatmasstransfer.2009.01.033 | en_US |
dc.identifier.journal | INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER | en_US |
dc.citation.volume | 52 | en_US |
dc.citation.issue | 13-14 | en_US |
dc.citation.spage | 3084 | en_US |
dc.citation.epage | 3090 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000266216700020 | - |
dc.citation.woscount | 6 | - |
顯示於類別: | 期刊論文 |