完整後設資料紀錄
DC 欄位語言
dc.contributor.author安帝亞en_US
dc.contributor.authorIswara, Aditya Pranaen_US
dc.contributor.author蔡春進en_US
dc.contributor.authorTsai, Chuen-Jinnen_US
dc.date.accessioned2014-12-12T02:39:59Z-
dc.date.available2014-12-12T02:39:59Z-
dc.date.issued2013en_US
dc.identifier.urihttp://140.113.39.130/cdrfb3/record/nctu/#GT070051733en_US
dc.identifier.urihttp://hdl.handle.net/11536/74166-
dc.description.abstractThis study used a parallel plate wet denuder coupled with ion chromatograph (PPWD-IC) to measure soluble gas pollutant concentrations and removal efficiency of packed towers. Gas pollutant concentrations measured by the PPWD-IC system were first validated with a manual porous metal denuder sampler (PDS) as a reference. Test results show that the collection efficiency of the PPWD-IC system operating at 5 L/min is nearly 100% for HF, HCl and CH3COOH, respectively. The comparison of these three gases show that concentration measured by the PPWD-IC system agree well with those obtained by PDS with correlation of determinant (R2) greater than 0.93. The PPWD was then applied to measure the removal efficiency of packed towers in high-tech factories continuously. Results show that the removal efficiency of gaseous pollutants is low and variable when the inlet concentration is low.zh_TW
dc.description.abstractThis study used a parallel plate wet denuder coupled with ion chromatograph (PPWD-IC) to measure soluble gas pollutant concentrations and removal efficiency of packed towers. Gas pollutant concentrations measured by the PPWD-IC system were first validated with a manual porous metal denuder sampler (PDS) as a reference. Test results show that the collection efficiency of the PPWD-IC system operating at 5 L/min is nearly 100% for HF, HCl and CH3COOH, respectively. The comparison of these three gases show that concentration measured by the PPWD-IC system agree well with those obtained by PDS with correlation of determinant (R2) greater than 0.93. The PPWD was then applied to measure the removal efficiency of packed towers in high-tech factories continuously. Results show that the removal efficiency of gaseous pollutants is low and variable when the inlet concentration is low.en_US
dc.language.isoen_USen_US
dc.subject氣體污染物zh_TW
dc.subject平行板濕溶蝕zh_TW
dc.subject多孔金屬溶蝕zh_TW
dc.subject測量堆棧zh_TW
dc.subjectGas pollutanten_US
dc.subjectparallel plate wet denuderen_US
dc.subjectporous metal denuderen_US
dc.subjectstack measurementen_US
dc.title以平行平板濕式固氣分離器探討填充式洗滌塔的去除效率zh_TW
dc.titleParallel Plate Wet Denuder for Studying Removal Efficiency of Packed Wet Scrubberen_US
dc.typeThesisen_US
dc.contributor.department環境工程系所zh_TW
顯示於類別:畢業論文