dc.description.abstractA disposable amperometric immunosensing strip was fabricated for rapid detection of Escherichia coli O157:H7. The method uses an indirect sandwich enzyme-linked immunoassay with double antibodies. Screen-printed carbon electrodes (SPCEs) were framed by commercial silver and carbon inks. For electrochemical characterization the carbon electrodes were coupled with the first E. coli O157:H7-specific antibody, E. coli O157:H7 intact cells and the second E. coli O157:H7-specific antibody conjugated with horseradish peroxidase (HRP). Hydrogen peroxide and ferrocenedicarboxylic acid (FeDC) were used as the substrate for HRP and mediator, respectively, at a potential +300 mV vs. counter/reference electrode. The response current (RC) of the immunosensing strips could be amplified significantly by 13-nm diameter Au nanoparticles (AuNPs) attached to the working electrode. The results show that the combined effects of AuNPs and FeDC enhanced RC by 13.1-fold. The SPCE immunosensing strips were used to detect E. coli O157:H7 specifically. Concentrations of E. coli O157:H7 from 10(2) to 10(7) CFU/ml could be detected. The detection limit was approximately 6 CFU/strip in PBS buffer and 50 CFU/strip in milk. The SPCE modified with AuNPs and FeDC has the potential for further applications and provides the basis for incorporating the method into an integrated system for rapid pathogen detection. (c) 2008 Elsevier B.V. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectEscherichia coli O157 : H7en_US
dc.subjectscreen-printed carbon electrodeen_US
dc.subjectimmunosensoren_US
dc.subjectelectrochemistryen_US
dc.subjectnanoparticlesen_US
dc.titleDisposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screen-printed carbon electrodes for the detection of foodborne pathogen Escherichia coli O157 : H7en_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.bios.2008.02.030en_US
dc.identifier.journalBIOSENSORS & BIOELECTRONICSen_US
dc.citation.volume23en_US
dc.citation.issue12en_US
dc.citation.spage1832en_US
dc.citation.epage1837en_US