Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chen, Sz-Hau | en_US |
dc.contributor.author | Wu, Vivian C. H. | en_US |
dc.contributor.author | Chuang, Yao-Chen | en_US |
dc.contributor.author | Lin, Chih-Sheng | en_US |
dc.date.accessioned | 2014-12-08T15:12:20Z | - |
dc.date.available | 2014-12-08T15:12:20Z | - |
dc.date.issued | 2008-04-01 | en_US |
dc.identifier.issn | 0167-7012 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.mimet.2008.01.004 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/9478 | - |
dc.description.abstract | A circulating-flow piezoelectric biosensor, based on an Au nanoparticle amplification and verification method, was used for real-time detection of a foodbome pathogen, Escherichia coli O157:H7. A synthesized thiolated probe (Probe 1; 30-mer) specific to E. coli O157:H7 eaeA gene was immobilized onto the piezoelectric biosensor surface. Hybridization was induced by exposing the immobilized probe to the E. coli O157:H7 eaeA gene fragment (104-bp) amplified by PCR, resulting in a mass change and a consequent frequency shift of the piezoelectric biosensor. A second thiolated probe (Probe 2), complementary to the target sequence, was conjugated to the An nanoparticles and used as a "mass enhancer" and "sequence verifier" to amplify the frequency change of the piezoelectric biosensor. The PCR products amplified from concentrations of 1.2 x 10(2) CFU/ml of E. coli O157:H7 were detectable by the piezoelectric biosensor. A linear correlation was found when the E. coli O157:H7 detected from 10(2) to 10(6) CFU/ml. The piezoelectric biosensor was able to detect targets from real food samples. (C) 2008 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Au nanoparticle | en_US |
dc.subject | piezoelectric biosensor | en_US |
dc.subject | E. coli O157 : H7 | en_US |
dc.title | Using oligonucleotide-functionalized Au nanoparticles to rapidly detect foodborne pathogens on a piezoelectric biosensor | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.mimet.2008.01.004 | en_US |
dc.identifier.journal | JOURNAL OF MICROBIOLOGICAL METHODS | en_US |
dc.citation.volume | 73 | en_US |
dc.citation.issue | 1 | en_US |
dc.citation.spage | 7 | en_US |
dc.citation.epage | 17 | en_US |
dc.contributor.department | 生物科技學系 | zh_TW |
dc.contributor.department | Department of Biological Science and Technology | en_US |
dc.identifier.wosnumber | WOS:000255300600002 | - |
dc.citation.woscount | 49 | - |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.