dc.description.abstractAn experiment is carried out in the present study to investigate the characteristics of the frictional pressure drops for the evaporation of refrigerants R-134a and R-407C in horizontal small tubes having the same inside diameter of 0.83 mm or 2.0 mm. In the experiment for the 2.0-mm tubes, the refrigerant mass flux G is varied from 200 to 400 kg/m(2) s, imposed heat flux q from 5 to 15 kW/m(2), inlet vapor quality x(in) from 0.2 to 0.8, and refrigerant saturation temperature T-sat from 5 to 15 degrees C. While for the 0.83-mm tubes, G is varied from 800 to 1500 kg/m(2) s with the other parameters varied in the same ranges as those for D-i = 2.0 mm. In this study, the effects of the inlet refrigerant vapor quality, mass flux, saturation temperature and imposed heat flux on the measured frictional pressure drops are examined in detail. Our experimental data clearly show that both the R-134a and R-407C frictional pressure drops increase significantly with the inlet vapor quality of the refrigerant, except at low mass flux and high heat flux. Besides, the effect of the imposed heat flux on the frictional pressure drop is rather weak. Moreover, a significant decrease in the frictional pressure drop results for a rise in T-sat. Furthermore, both the R-134a and R-407C frictional pressure drops increase substantially with the refrigerant mass flux. We also note that under the same x(in), T-sat, q and D-i, refrigerant R-407C has a lower frictional pressure drop when compared with that for R-134a. For the same refrigerant, a reduction in the duct size from 2.0-mm to 0.83-mm causes a significant increase in Delta P-f. Finally, an empirical correlation for the friction factor for the R-134a and R-407C evaporation in the 0.83-mm and 2.0-mm small tubes is proposed. (C) 2007 Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.titleExperimental study of evaporation pressure drop characteristics of refrigerants R-134a and R-407C in horizontal small tubesen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.ijheatmasstransfer.2007.03.046en_US
dc.identifier.journalINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFERen_US
dc.citation.volume51en_US
dc.citation.issue1-2en_US
dc.citation.spage294en_US
dc.citation.epage301en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000252688800028-
dc.citation.woscount1-
顯示於類別:期刊論文


文件中的檔案:

  1. 000252688800028.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。