Differences in PM10 concentrations measured by beta-gauge monitor and hi-vol sampler

dc.citation.epage5748en_US
dc.citation.issue33en_US
dc.citation.spage5741en_US
dc.citation.volume35en_US
dc.citation.woscount26
dc.contributor.authorChang, CTen_US
dc.contributor.authorTsai, CJen_US
dc.contributor.authorLee, CTen_US
dc.contributor.authorChang, SYen_US
dc.contributor.authorCheng, MTen_US
dc.contributor.authorChein, HMen_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.date.accessioned2014-12-08T15:43:17Z
dc.date.available2014-12-08T15:43:17Z
dc.date.issued2001-11-01en_US
dc.description.abstractIn this paper. differences between the 24-h average PM10 concentrations of Wedding beta -gauge monitor and Andersen or Wedding hi-vol sampler were studied. When the deliquescent point is not exceeded, PM10 concentrations of the beta -gauge are close to those of the manual samplers. The ratio of beta -gauge PM10 to Andersen PM10 and Wedding PM10 is 1.08 +/-0.06 and 1.09 +/-0.12, respectively. However, when the deliquescent point is exceeded, water absorption by the inorganics of aerosols leads to higher PM10 concentrations of the beta -gauge compared to those of the manual sampler. The ratio of beta -gauge PM10 to Andersen PM10 and Wedding PM10 is 1.21 +/-0.22 and 1.27 +/-0.15, respectively. However., due to evaporation of water from the aerosols collected on the filter tape of the beta -gauge, differences in PM10 concentrations are much less than theoretically calculated. (C) 2001 Elsevier Science Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/S1352-2310(01)00369-7en_US
dc.identifier.issn1352-2310en_US
dc.identifier.journalATMOSPHERIC ENVIRONMENTen_US
dc.identifier.urihttp://dx.doi.org/10.1016/S1352-2310(01)00369-7en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/29291
dc.identifier.wosnumberWOS:000172354900005
dc.language.isoen_USen_US
dc.subjectbeta-gaugeen_US
dc.subjectwater contenten_US
dc.subjectPM10en_US
dc.subjectrelative humidityen_US
dc.titleDifferences in PM10 concentrations measured by beta-gauge monitor and hi-vol sampleren_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000172354900005.pdf
Size:
191.44 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: