<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Seismic design and shake table tests of a steel post-tensioned self-centering moment frame with a slab accommodating frame expansion

dc.citation.epage1261en_US
dc.citation.issue11en_US
dc.citation.spage1241en_US
dc.citation.volume40en_US
dc.citation.woscount18
dc.contributor.authorChou, Chung-Cheen_US
dc.contributor.authorChen, Jun-Henen_US
dc.contributor.department土木工程學系zh_TW
dc.contributor.departmentDepartment of Civil Engineeringen_US
dc.date.accessioned2014-12-08T15:27:36Z
dc.date.available2014-12-08T15:27:36Z
dc.date.issued2011-09-01en_US
dc.description.abstractPost-tensioned (PT) self-centering moment frames were developed as an alternative to welded moment-resisting frames (MRFs). Lateral deformation of a PT frame opens gaps between beams and columns. The use of a composite slab in welded MRFs limits the opening of gaps at the beam-to-column interfaces but cannot be adopted in PT self-centering frames. In this study, a sliding slab is used to minimize restraints to the expansion of the PT frame. A composite slab is rigidly connected to the beams in a single bay of the PT frame. A sliding device is installed between the floor beams and the beams in other bays, wherever the slab is allowed to slide. Many shaking table tests were conducted on a reduced-scale, two-by-two bay one-story specimen, which comprised one PT frame and two gravitational frames (GFs). The PT frame and GFs were self-centering throughout the tests, responding in phase with only minor differences in peak drifts that were caused by the expansion of the PT frame. When the specimen was excited by the 1999 Chi-Chi earthquake with a peak ground acceleration of 1.87g, the maximum interstory drift was 7.2% and the maximum lateral force was 270 kN, equal to 2.2 times the yield force of the specimen. Buckling of the beam bottom flange was observed near the column face, and the initial post-tensioning force in the columns and beams decreased by 50 and 22%, respectively. However, the specimen remained self-centering and its residual drift was 0.01%. Copyright (C) 2011 John Wiley & Sons, Ltd.en_US
dc.identifier.doi10.1002/eqe.1086en_US
dc.identifier.issn0098-8847en_US
dc.identifier.journalEARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICSen_US
dc.identifier.urihttp://dx.doi.org/10.1002/eqe.1086en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/19859
dc.identifier.wosnumberWOS:000294176800004
dc.language.isoen_USen_US
dc.subjectpost-tensioned frameen_US
dc.subjectframe expansionen_US
dc.subjectslab slidingen_US
dc.subjectshake table testsen_US
dc.titleSeismic design and shake table tests of a steel post-tensioned self-centering moment frame with a slab accommodating frame expansionen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000294176800004.pdf
Size:
1.13 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: