Analysis and Solution to Overcome EOS Failure Induced by Latchup Test in A High-Voltage Integrated Circuits
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
Abstract
Proper layout and additional circuit solution have been proposed to solve the practical EOS failure induced by latchup test in an industry case of high-voltage integrated circuits (IC). The modified design has been implemented in 0.6-um 40-V BCD (Bipolar-CMOS-DMOS) process to successfully pass the 500-mA negative trigger current test. By eliminating overstress damages as happened in the prior work with only guard ring protection, the proposed solution can be adopted to implement high-voltage-applicable IC products which meet the requirement of industry applications with sufficient latchup immunity.