<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

A study of reinforced concrete corner columns after fire

dc.citation.epage638en_US
dc.citation.issue7en_US
dc.citation.spage622en_US
dc.citation.volume30en_US
dc.citation.woscount12
dc.contributor.authorJau, Wen-Chenen_US
dc.contributor.authorHuang, Kuo-Lien_US
dc.contributor.department土木工程學系zh_TW
dc.contributor.departmentDepartment of Civil Engineeringen_US
dc.date.accessioned2014-12-08T15:11:06Z
dc.date.available2014-12-08T15:11:06Z
dc.date.issued2008-08-01en_US
dc.description.abstractThis study investigated the behavior of corner columns under axial loading, biaxial bending and asymmetric fire loading. It is found that, under a longitudinal stress ratio of 0.1f'(c), the residual strength ratios of the columns after fire loading show: (a) the 2 and 4 h fire loadings result in residual strength ratios of 67% and 57%, respectively; a 10% reduction on residual strength results as the duration changes from 2 to 4 h; (b) reductions in reinforcing steel ratio cause lower residual strength ratios; and (c) increasing the thickness of concrete cover causes lower residual strength ratios. It was also found that the temperature distribution across the cross-section is not affected by concrete cover thickness and steel ratio. The residual strengths can be used for future evaluation, repair and strengthening. (C) 2007 Elsevier Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.cemconcomp.2007.09.009en_US
dc.identifier.issn0958-9465en_US
dc.identifier.journalCEMENT & CONCRETE COMPOSITESen_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.cemconcomp.2007.09.009en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/8513
dc.identifier.wosnumberWOS:000257974700009
dc.language.isoen_USen_US
dc.subjectmechanical propertiesen_US
dc.subjecthigh temperatureen_US
dc.subjectresidual strengthen_US
dc.subjectresidual strength ratioen_US
dc.subjectcorner columnen_US
dc.subjectreinforced concreteen_US
dc.titleA study of reinforced concrete corner columns after fireen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000257974700009.pdf
Size:
732.83 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: