<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Optical assessment of the cardiac rhythm of contracting cardiomyocytes in vitro and a pulsating heart in vivo for pharmacological screening

dc.citation.epage1625en_US
dc.citation.issue5en_US
dc.citation.spage1616en_US
dc.citation.volume5en_US
dc.citation.woscount0
dc.contributor.authorLai, Yu-Chengen_US
dc.contributor.authorChang, Wei-Tienen_US
dc.contributor.authorLin, Kuen-Youen_US
dc.contributor.authorLiau, Ianen_US
dc.contributor.department應用化學系zh_TW
dc.contributor.department應用化學系分子科學碩博班zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.contributor.departmentInstitute of Molecular scienceen_US
dc.date.accessioned2014-12-08T15:36:07Z
dc.date.available2014-12-08T15:36:07Z
dc.date.issued2014-05-01en_US
dc.description.abstractOur quest in the pathogenesis and therapies targeting human heart diseases requires assessment of the contractile dynamics of cardiac models of varied complexity, such as isolated cardiomyocytes and the heart of a model animal. It is hence beneficial to have an integral means that can interrogate both cardiomyocytes in vitro and a heart in vivo. Herein we report an application of dual-beam optical reflectometry to determine noninvasively the rhythm of two representative cardiac models-chick embryonic cardiomyocytes and the heart of zebrafish. We probed self-beating cardiomyocytes and revealed the temporally varying contractile frequency with a short-time Fourier transform. Our unique dual-beam setup uniquely records the atrial and ventricular pulsations of zebrafish simultaneously. To minimize the cross talk between signals associated with atrial and ventricular chambers, we particularly modulated the two probe beams at distinct frequencies and extracted the signals specific to individual cardiac chambers with phase-sensitive detection. With this setup, we determined the atrio-ventricular interval, a parameter that is manifested by the electrical conduction from the atrium to the ventricle. To demonstrate pharmacological applications, we characterized zebrafish treated with various cardioactive and cardiotoxic drugs, and identified abnormal cardiac rhythms and atrioventricular (AV) blocks of varied degree. In light of its potential capability to assess cardiac models both in vitro and in vivo and to screen drugs with cardioactivity or toxicity, we expect this approach to have broad applications ranging from cardiopharmacology to developmental biology. (C) 2014 Optical Society of Americaen_US
dc.identifier.doi10.1364/BOE.5.001616en_US
dc.identifier.issn2156-7085en_US
dc.identifier.journalBIOMEDICAL OPTICS EXPRESSen_US
dc.identifier.urihttp://dx.doi.org/10.1364/BOE.5.001616en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/24463
dc.identifier.wosnumberWOS:000335494600024
dc.language.isoen_USen_US
dc.titleOptical assessment of the cardiac rhythm of contracting cardiomyocytes in vitro and a pulsating heart in vivo for pharmacological screeningen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000335494600024.pdf
Size:
1.42 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: