Perturbation On-time (POT) Control and Inhibit Time Control (ITC) in Suppression of THD of Power Factor Correction (PFC) Design
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
DOI
Abstract
The paper presented the perturbation on-time (POT) control technique to suppress the total harmonic distortion (THD) to improve the performance of the power factor correction (PFC) in the AC-DC converter. Simultaneously, it can improve the efficiency through the proposed inhibit time control (ITC) mechanism at low AC input voltage. The test circuit fabricated in TSMC 800V UHV process can show the highly-integrated PFC controller. Experimental results demonstrate low THD of 8%, which results in high PF of 99%. Besides, high efficiency of 95% can be ensured at the output power of 90W.