Sampling time effect on 2,4-Toluene diisocyanate concentration by using different samplers

dc.citation.epage1812en_US
dc.citation.issue9en_US
dc.citation.spage1799en_US
dc.citation.volume41en_US
dc.citation.woscount0
dc.contributor.authorTsai, CJen_US
dc.contributor.authorLin, HCen_US
dc.contributor.authorLin, KYen_US
dc.contributor.authorShih, TSen_US
dc.contributor.authorChang, KCen_US
dc.contributor.authorHung, IFen_US
dc.contributor.authorDeshpande, CGen_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.date.accessioned2014-12-08T15:17:49Z
dc.date.available2014-12-08T15:17:49Z
dc.date.issued2006en_US
dc.description.abstractIn order to understand the sampling time effect on the 2,4-TDI (Toluene diisocyanate) concentrations, laboratory and field tests were conducted in this study. An ADS (annular denuder sampler) and two OFFCs (open face filter holders) with different filters were tested for 1 to 120 minutes in the laboratory using 2,4-TDI gas. In the field study, the standard sampling method, the dual filter the triple filter and annular denuder systems were used at two workplaces to study the change of 2,4-TDI concentrations with sampling time from 15 to 60 minutes. The test results in both laboratory and field studies show that the sampling time influences the sampled TDI concentration considerably which may be due to reaction of TDI with water vapor and polyo in the sampling process. It is evident that as sampling time increases the TDI concentration decreases very significantly.en_US
dc.identifier.doi10.1080/01496390600634780en_US
dc.identifier.issn0149-6395en_US
dc.identifier.journalSEPARATION SCIENCE AND TECHNOLOGYen_US
dc.identifier.urihttp://dx.doi.org/10.1080/01496390600634780en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/12902
dc.identifier.wosnumberWOS:000238419800003
dc.language.isoen_USen_US
dc.subjectToluene diisocynanateen_US
dc.subjectsampling methoden_US
dc.subjectdenuder sampleren_US
dc.subjectfilter sampleren_US
dc.titleSampling time effect on 2,4-Toluene diisocyanate concentration by using different samplersen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000238419800003.pdf
Size:
156.51 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: