<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

A Power-Efficient Bio-Potential Acquisition Device with DS-MDE Sensors for Long-Term Healthcare Monitoring Applications

dc.citation.epage4793en_US
dc.citation.issue5en_US
dc.citation.spage4777en_US
dc.citation.volume10en_US
dc.citation.woscount6
dc.contributor.authorChang, Chia-Linen_US
dc.contributor.authorChang, Chih-Weien_US
dc.contributor.authorHuang, Hong-Yien_US
dc.contributor.authorHsu, Chen-Mingen_US
dc.contributor.authorHuang, Chia-Hsuanen_US
dc.contributor.authorChiou, Jin-Chernen_US
dc.contributor.authorLuo, Ching-Hsingen_US
dc.contributor.department電機工程學系zh_TW
dc.contributor.departmentDepartment of Electrical and Computer Engineeringen_US
dc.date.accessioned2014-12-08T15:07:01Z
dc.date.available2014-12-08T15:07:01Z
dc.date.issued2010-05-01en_US
dc.description.abstractThis work describes a power-efficient bio-potential acquisition device for long-term healthcare applications that is implemented using novel microelectromechanical dry electrodes (MDE) and a low power bio-potential processing chip. Using micromachining technology, an attempt is also made to enhance the sensing reliability and stability by fabricating a diamond-shaped MDE (DS-MDE) that has a satisfactory self-stability capability and superior electric conductivity when attached onto skin without any extra skin tissue injury technology. To acquire differential bio-potentials such as ECG signals, the proposed processing chip fabricated in a standard CMOS process has a high common mode rejection ratio (C. M. R. R.) differential amplifier and a 12-bit analog-to-digital converter (ADC). Use of the proposed system and integrate simple peripheral commercial devices can obtain the ECG signal efficiently without additional skin tissue injury and ensure continuous monitoring more than 70 hours with a 400 mAh battery.en_US
dc.identifier.doi10.3390/s100504777en_US
dc.identifier.issn1424-8220en_US
dc.identifier.journalSENSORSen_US
dc.identifier.urihttp://dx.doi.org/10.3390/s100504777en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/5487
dc.identifier.wosnumberWOS:000278105100033
dc.language.isoen_USen_US
dc.subjectDS-MDEen_US
dc.subjectbio-potential acquisition chipen_US
dc.subjectlong-term ECG monitoringen_US
dc.titleA Power-Efficient Bio-Potential Acquisition Device with DS-MDE Sensors for Long-Term Healthcare Monitoring Applicationsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000278105100033.pdf
Size:
521.87 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: