<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Development of a balanced detector with biased synchronous detection and application to near shot noise limited noise cancelling of supercontinuum pulse light

dc.citation.epageen_US
dc.citation.issue2en_US
dc.citation.volume85en_US
dc.citation.woscount1
dc.contributor.authorSeto, Keisukeen_US
dc.contributor.authorTsukada, Toshiakien_US
dc.contributor.authorOkuda, Yoshinaoen_US
dc.contributor.authorTokunaga, Eijien_US
dc.contributor.authorKobayashi, Takayoshien_US
dc.contributor.department電子物理學系zh_TW
dc.contributor.departmentDepartment of Electrophysicsen_US
dc.date.accessioned2014-12-08T15:36:09Z
dc.date.available2014-12-08T15:36:09Z
dc.date.issued2014-02-01en_US
dc.description.abstractWe report on the development of a balanced detector suited for multicolor imaging. The source pulsed light is split into probe and reference pulsed light. The reference pulse is delayed through an optical path and the probe and reference pulses are detected by a single photodetector. The signs of the detected signals of the probe and reference pulses are flipped based on a signal synchronous to the light source. Then, the signals are averaged through a low-pass filter. The output signal is proportional to the intensity difference between the probe and the reference. This balanced detector has two features: (1) both the probe and reference pulsed lights are detected by a single photodetector and (2) a voltage bias on the sign flipping compensates for the optical-intensity unbalance between the probe and reference pulsed lights. The first feature enables the probe and reference pulses to travel along a common optical path from a sample through a spectrograph to the photodetector, which minimizes the intensity unbalance between the probe and reference pulses during imaging and spectroscopy. The second feature ensures the complete balanced-detection in whole wavelength range by compensating for the optical unbalance created by deviations in the splitting ratios of the probe and reference lights at different wavelengths. Although a higher signal to noise ratio (SNR) reached to near shot noise limited SNR is attained by attaching a resonator to the photodetector for pulse repetition, the electrical bias cannot compensate for the optical balance. This unbalance is, however, corrected by adjusting the phase of the synchronous signal. We applied the present balanced detection to a stimulated Raman microscope with supercontinuum probe light and demonstrated its noise cancelling performance through capturing polystyrene beads. (C) 2014 AIP Publishing LLC.en_US
dc.identifier.doi10.1063/1.4863879en_US
dc.identifier.issn0034-6748en_US
dc.identifier.journalREVIEW OF SCIENTIFIC INSTRUMENTSen_US
dc.identifier.urihttp://dx.doi.org/10.1063/1.4863879en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/24509
dc.identifier.wosnumberWOS:000335919900265
dc.language.isoen_USen_US
dc.titleDevelopment of a balanced detector with biased synchronous detection and application to near shot noise limited noise cancelling of supercontinuum pulse lighten_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000335919900265.pdf
Size:
875.14 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: