<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Determination of cocaine and its metabolites using cation-selective exhaustive injection and sweeping-MEKC

dc.citation.epage4276en_US
dc.citation.issue20en_US
dc.citation.spage4270en_US
dc.citation.volume29en_US
dc.citation.woscount15
dc.contributor.authorSu, Hsiu-Lien_US
dc.contributor.authorFeng, Lan-Ingen_US
dc.contributor.authorJen, Hsiu-Pingen_US
dc.contributor.authorHsieh, You-Zungen_US
dc.contributor.department應用化學系zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.date.accessioned2014-12-08T15:10:43Z
dc.date.available2014-12-08T15:10:43Z
dc.date.issued2008-11-01en_US
dc.description.abstractWe have employed a high-sensitivity on-line preconcentration method, cation-selective exhaustive injection (CSEI) and sweeping MEKC, for the analysis of cocaine, benzoylecgonine, norcocaine, and cocaethylene. We monitored the effects of several of the CSEI-sweeping-MEKC parameters - including the pH, the concentrations of SDS and organic modifier, the injection length of the high-conductivity buffer, and the injection time of the sample - to optimize the separation process. The optimal BGE was 100 mM phosphoric acid (pH 1.8) containing 75 mM SDS with 10% 2-propanol and 10% tetrahydrofuran as the organic modifier. In addition, electrokinetic injection of the sample at 15 kV for 900 s provided both high separation efficiency and enhanced sweeping sensitivity. The sensitivity enhancements for cocaine, norcocaine, and cocaethylene ranged from 2.06 x 10(4) to 3.96 x 10(4); for benzoylecgonine it was 1.75 x 10(3); the coefficients of determination exceeded 0.9958. The LODs, based on an SIN ratio of 3:1, of sweeping-MEKC ranged from 33.5 to 52.8 ng/mL; in contrast, when using CSEI-sweeping-MEKC the sensitivity increased to range from 29.7 to 236 pg/mL. Under the optimal conditions, we analyzed cocaine in a human urine sample prepared using off-line SPE to minimize the influence of the matrix. The recovery of the SPE efficiency was satisfactory (ca. 74.9-87.6%). Our experimental results suggest that, under the optimal conditions, the CSEI-sweeping-MEKC method can be used to determine cocaine and its metabolites with high sensitivity in human urine.en_US
dc.identifier.doi10.1002/elps.200800167en_US
dc.identifier.issn0173-0835en_US
dc.identifier.journalELECTROPHORESISen_US
dc.identifier.urihttp://dx.doi.org/10.1002/elps.200800167en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/8193
dc.identifier.wosnumberWOS:000261456400016
dc.language.isoen_USen_US
dc.subjectCocaine and its metabolitesen_US
dc.subjectCSEI-sweeping-MEKCen_US
dc.subjectOn-line preconcentrationen_US
dc.subjectSweeping-MEKCen_US
dc.titleDetermination of cocaine and its metabolites using cation-selective exhaustive injection and sweeping-MEKCen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000261456400016.pdf
Size:
128.46 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: