<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Measurement of cosmic-ray muons and muon-induced neutrons in the Aberdeen Tunnel Underground Laboratory

dc.citation.epage0en_US
dc.citation.issue7en_US
dc.citation.spage0en_US
dc.citation.volume93en_US
dc.citation.woscount3en_US
dc.contributor.authorBlyth, S. C.en_US
dc.contributor.authorChan, Y. L.en_US
dc.contributor.authorChen, X. C.en_US
dc.contributor.authorChu, M. C.en_US
dc.contributor.authorCui, K. X.en_US
dc.contributor.authorHahn, R. L.en_US
dc.contributor.authorHo, T. H.en_US
dc.contributor.authorHsiung, Y. B.en_US
dc.contributor.authorHu, B. Z.en_US
dc.contributor.authorKwan, K. K.en_US
dc.contributor.authorKwok, M. W.en_US
dc.contributor.authorKwok, T.en_US
dc.contributor.authorLau, Y. P.en_US
dc.contributor.authorLeung, J. K. C.en_US
dc.contributor.authorLeung, K. Y.en_US
dc.contributor.authorLin, G. L.en_US
dc.contributor.authorLin, Y. C.en_US
dc.contributor.authorLuk, K. B.en_US
dc.contributor.authorLuk, W. H.en_US
dc.contributor.authorNgai, H. Y.en_US
dc.contributor.authorNgan, S. Y.en_US
dc.contributor.authorPun, C. S. J.en_US
dc.contributor.authorShih, K.en_US
dc.contributor.authorTam, Y. H.en_US
dc.contributor.authorTsang, R. H. M.en_US
dc.contributor.authorWang, C. H.en_US
dc.contributor.authorWong, C. M.en_US
dc.contributor.authorWong, H. L. H.en_US
dc.contributor.authorWong, K. K.en_US
dc.contributor.authorYeh, M.en_US
dc.contributor.authorZhang, B. J.en_US
dc.contributor.department物理研究所zh_TW
dc.contributor.departmentInstitute of Physicsen_US
dc.date.accessioned2019-04-03T06:42:14Z
dc.date.available2019-04-03T06:42:14Z
dc.date.issued2016-04-07en_US
dc.description.abstractWe have measured the muon flux and production rate of muon-induced neutrons at a depth of 611 m water equivalent. Our apparatus comprises three layers of crossed plastic scintillator hodoscopes for tracking the incident cosmic-ray muons and 760 L of a gadolinium-doped liquid scintillator for producing and detecting neutrons. The vertical muon intensity was measured to be I-mu = (5.7 +/- 0.6) x 10(-6) cm(-2) s(-1) sr(-1). The yield of muon-induced neutrons in the liquid scintillator was determined to be Y-n = (1.19 +/- 0.08(stat) +/- 0.21(syst)) x 10(-4) neutrons/(mu.g.cm(-2)). A fit to the recently measured neutron yields at different depths gave a mean muon energy dependence of < E-mu >(0.76 +/- 0.03) for liquid-scintillator targets.en_US
dc.identifier.doi10.1103/PhysRevD.93.072005en_US
dc.identifier.issn2470-0010en_US
dc.identifier.journalPHYSICAL REVIEW Den_US
dc.identifier.urihttp://dx.doi.org/10.1103/PhysRevD.93.072005en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/133420
dc.identifier.wosnumberWOS:000373578900002en_US
dc.language.isoen_USen_US
dc.titleMeasurement of cosmic-ray muons and muon-induced neutrons in the Aberdeen Tunnel Underground Laboratoryen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
8e73021859f77ba8260479753cd9a21d.pdf
Size:
2.05 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: