<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Methodology of Generating Dual-Cell-Aware Tests

Abstract

This paper introduces a novel fault model, called the dual-cell-aware (DCA) fault model, which targets the short defects locating between two adjacent standard cells placed in the layout. A layout-based methodology is also presented to automatically extract valid DCA faults from targeted designs and cell libraries. The identified DCA faults are outputted in a format that can be applied to a commercial ATPG tool for test generation. The result of ATPG and fault simulation based on industrial designs have demonstrated that the DCA faults cannot be fully covered by the tests of conventional fault models including stuck-at, transition, bridge and cell-aware faults and hence require their own designated tests to detect.

Description

Keywords

Citation

Endorsement

Review

Supplemented By

Referenced By