<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Spatiotemporal effects of a bioautocatalytic chemical wave revealed by time-resolved mass spectrometry

dc.citation.epage2108en_US
dc.citation.issue5en_US
dc.citation.spage2103en_US
dc.citation.volume4en_US
dc.citation.woscount4
dc.contributor.authorTing, Hsuen_US
dc.contributor.authorUrban, Pawel L.en_US
dc.contributor.department應用化學系zh_TW
dc.contributor.department應用化學系分子科學碩博班zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.contributor.departmentInstitute of Molecular scienceen_US
dc.date.accessioned2014-12-08T15:33:56Z
dc.date.available2014-12-08T15:33:56Z
dc.date.issued2014en_US
dc.description.abstractMass spectrometry has been implemented as an on-line detection tool to monitor transmission of chemical signals due to natural processes such as diffusion and convection as well as a bienzymatic autocatalytic process. It was found that the enzyme-accelerated chemical wave propagates faster than the chemical wave propelled by other processes. The two enzymes (pyruvate kinase and adenylate kinase), involved in the process, work co-operatively catalysing production of adenosine diphosphate (ADP) and adenosine triphosphate (ATP), and induce formation of a front propagating along a high-aspect-ratio drift cell towards the ion source of an ion trap mass spectrometer. Isotopically labelled C-13-ATP was used as the trigger of the accelerated chemical wave. Using this substrate, one could easily distinguish between the two chemical waves (passive and accelerated) in a single experiment, reducing the bias due to the inherent experimental instabilities. We think that - following further improvements - the process described in this report may find applications in bioengineered systems, in which chemical signals need to be transmitted over macroscopic distances.en_US
dc.identifier.doi10.1039/c3ra42873gen_US
dc.identifier.issn2046-2069en_US
dc.identifier.journalRSC ADVANCESen_US
dc.identifier.urihttp://dx.doi.org/10.1039/c3ra42873gen_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/23394
dc.identifier.wosnumberWOS:000329035400001
dc.language.isoen_USen_US
dc.titleSpatiotemporal effects of a bioautocatalytic chemical wave revealed by time-resolved mass spectrometryen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000329035400001.pdf
Size:
399.26 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: