Solid-Phase Thermodynamic Interpretation of Ion Desorption in Matrix-Assisted Laser Desorption/Ionization

dc.citation.epage13852en_US
dc.citation.issue43en_US
dc.citation.spage13847en_US
dc.citation.volume114en_US
dc.citation.woscount8
dc.contributor.authorLai, Yin-Hungen_US
dc.contributor.authorWang, Chia-Chenen_US
dc.contributor.authorLin, Sheng-Hsianen_US
dc.contributor.authorLee, Yuan Tsehen_US
dc.contributor.authorWang, Yi-Shengen_US
dc.contributor.department交大名義發表zh_TW
dc.contributor.departmentNational Chiao Tung Universityen_US
dc.date.accessioned2014-12-08T15:47:46Z
dc.date.available2014-12-08T15:47:46Z
dc.date.issued2010-11-04en_US
dc.description.abstractThis work demonstrates a quantitative interpretation of ion desorption in matrix-assisted laser desorption/ionization (MALDI). The theoretical modeling incorporates transition state theory for the desorption of surface ions, assuming chemical and thermal equilibrium in the solid state prior to desorption. It is distinct from conventional models that assume chemical equilibrium in the gas phase. This solid-state thermodynamic interpretation was used to examine the desorption of pure 2,4,6-trihydroxyacetophenone (THAP) and of angiotensin I mixed with THAP. It successfully described the changes in ion yield with the effective temperature under various laser fluence and initial temperature conditions. The analysis also revealed the key role played by ion concentration in the modeling to provide the best fit of the model to observations. On the other hand, divergence of the ion beam with laser fluence was examined using an imaging detection method, and the signal saturation normally seen at high fluence was appropriately reduced by ion focusing. Simplified but deceptive theoretical interpretations were obtained when the analysis was conducted without adequate calibration of the instrument bias.en_US
dc.identifier.doi10.1021/jp104250gen_US
dc.identifier.issn1520-6106en_US
dc.identifier.journalJOURNAL OF PHYSICAL CHEMISTRY Ben_US
dc.identifier.urihttp://dx.doi.org/10.1021/jp104250gen_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/31945
dc.identifier.wosnumberWOS:000283519600027
dc.language.isoen_USen_US
dc.titleSolid-Phase Thermodynamic Interpretation of Ion Desorption in Matrix-Assisted Laser Desorption/Ionizationen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000283519600027.pdf
Size:
185.63 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: