<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

Highly sensitive color-indicating and quantitative biosensor based on cholesteric liquid crystal

dc.citation.epage5038en_US
dc.citation.issue12en_US
dc.citation.spage5033en_US
dc.citation.volume6en_US
dc.citation.woscount12en_US
dc.contributor.authorHsiao, Yu-Chengen_US
dc.contributor.authorSung, Yu-Chienen_US
dc.contributor.authorLee, Mon-Juanen_US
dc.contributor.authorLee, Weien_US
dc.contributor.department影像與生醫光電研究所zh_TW
dc.contributor.departmentInstitute of Imaging and Biomedical Photonicsen_US
dc.date.accessioned2019-04-03T06:44:37Z
dc.date.available2019-04-03T06:44:37Z
dc.date.issued2015-12-01en_US
dc.description.abstractLiquid crystal (LC)-based biosensors employ highly sensitive interfaces between the alignment layers and LCs to detect biomolecules and their interactions. Present techniques based on optical texture observation of the homeotropic-to-planar response of nematic LCs are limited by their quantitative reproducibility of results, indicating that both the accuracy and reliability of LC-based detection require further improvements. Here we show that cholesteric LC (CLC) can be used as a novel sensing element in the design of an alternative LC-based biosensing device. The chirality of the vertically anchored (VA) CLC was exploited in the detection of bovine serum albumin (BSA), a protein standard commonly used in protein quantitation. The color appearance and the corresponding transmission spectrum of the cholesteric phase changed with the concentration of BSA, by which a detection limit of 1 fg/ml was observed. The optical response of the VA CLC interface offers a simple and inexpensive platform for highly sensitive and naked-eye color-indicating detection of biomolecules, and, thus, may facilitate the development of point-of-care devices for the detection of disease-related biomarkers. (C) 2015 Optical Society of Americaen_US
dc.identifier.doi10.1364/BOE.6.005033en_US
dc.identifier.issn2156-7085en_US
dc.identifier.journalBIOMEDICAL OPTICS EXPRESSen_US
dc.identifier.urihttp://dx.doi.org/10.1364/BOE.6.005033en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/129341
dc.identifier.wosnumberWOS:000366122800034en_US
dc.language.isoen_USen_US
dc.titleHighly sensitive color-indicating and quantitative biosensor based on cholesteric liquid crystalen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
881151af4a0010c873abcba5e5d68934.pdf
Size:
3.83 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: