<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css"> Skip to main content

On the heat transfer correlation for membrane distillation

dc.citation.epage1973en_US
dc.citation.issue4en_US
dc.citation.spage1968en_US
dc.citation.volume52en_US
dc.citation.woscount5
dc.contributor.authorWang, Chi-Chuanen_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.date.accessioned2014-12-08T15:11:50Z
dc.date.available2014-12-08T15:11:50Z
dc.date.issued2011-04-01en_US
dc.description.abstractThe present study examines the heat transfer coefficients applicable for membrane distillation. In the available literatures, researchers often adopt some existing correlations and claim the suitability of these correlations to their test data or models. Unfortunately this approach is quite limited and questionable. This is subject to the influences of boundary conditions, geometrical configurations, entry flow conditions, as well as some influences from spacer or support. The simple way is to obtain the heat transfer coefficients from experimentation. However there is no direct experimental data for heat transfer coefficients being reported directly from the measurements. The main reasons are from the uncertainty of permeate side and of the comparatively large magnitude of membrane resistance. Additional minor influence is the effect of mass transfer on the heat transfer performance. In practice, the mass transfer effect is negligible provided the feed side temperature is low. To increase the accuracy of the measured feed side heat transfer coefficient, it is proposed in this study to exploit a modified Wilson plot technique. Through this approach, one can eliminate the uncertainty from permeate side and reduce the uncertainty in membrane to obtain a more reliable heat transfer coefficients at feed side from the experimentation. (C) 2010 Elsevier Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.enconman.2010.11.014en_US
dc.identifier.issn0196-8904en_US
dc.identifier.journalENERGY CONVERSION AND MANAGEMENTen_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.enconman.2010.11.014en_US
dc.identifier.urihttps://ir.lib.nycu.edu.tw/handle/11536/9083
dc.identifier.wosnumberWOS:000287555700023
dc.language.isoen_USen_US
dc.subjectMembrane distillationen_US
dc.subjectHeat transfer coefficienten_US
dc.subjectWilson ploten_US
dc.titleOn the heat transfer correlation for membrane distillationen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
000287555700023.pdf
Size:
353.18 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: