標題: A continuous stirred tank reactor study on chromic acid removal by ion exchange
作者: Tan, HKS
應用化學系
Department of Applied Chemistry
公開日期: 1998
摘要: Dilute chromic acid removal by anion exchange was studied using a continuous stirred tank reactor (CSTR) system. A rate model based on film diffusion control was formulated for quantitative study on the chromate removal. For simplicity, the rate and mass balance equations were formulated for total Cr(VT) concentration. Equations were derived for the effluent concentration history as well as the time-dependent Cr(VI) concentration in the resin. The derived equations for solid and liquid phase Cr(VI) concentration variations were tested and verified by the experimental results obtained. Effects of various operating conditions, such as resin size, feed concentration, and flow rate, were also discussed.
URI: http://hdl.handle.net/11536/106
ISSN: 0149-6395
期刊: SEPARATION SCIENCE AND TECHNOLOGY
Volume: 33
Issue: 8
起始頁: 1089
結束頁: 1106