標題: Effects of plasma treatment on the high frequency characteristics of Cu/Ta/hydrogen silsesquioxane (HSQ) system and electrical behaviors of Cu/Ta/HSQ/Pt MIM capacitors
作者: Ho, Chia-Cheng
Chiou, Bi-Shiou
電子工程學系及電子研究所
Innovative Packaging Research Center
Department of Electronics Engineering and Institute of Electronics
Innovative Packaging Research Center
關鍵字: hydrogen silsesquioxane;interconnect;insertion loss;plasma treatment
公開日期: 1-四月-2007
摘要: With the increasing of the operating frequencies, insertion loss, signal propagation delay, and parasitic coupling capacitance become the significant problems. Small capacitance (C) between interconnects is required to reduce the crosstalk, insertion loss, and RC delay associated with the metal interconnect system. Therefore, the interconnect with low dielectric constant (k) material is required. Implementation of Cu/low-k dielectric is used for reducing insertion loss, RC delay, crosstalk noises, etc. In this work, Cu-hydrogen silsesquioxane (HSQ) systems are studied. Ammonia (NH3) plasma is employed for the nitridation of HSQ. The effects of NH3 plasma treatments on the high frequency characteristics (100 MHz to 20 GHz) of the interconnect structure Cu/Ta/HSQ and electrical behaviors of Cu/Ta/HSQ/Pt MIM capacitors are evaluated. Auger electron spectroscopy (AES) results suggest the diffusion of oxygen and copper atoms during copper annealing. This raises resistance of Cu interconnect and increases the conductance of the HSQ films. Hence, 400 degrees C-annealed Cu/Ta/HSQ interconnect systems become lossy at high frequencies (> 2 GHz). Ammonia (NH3) plasma bombardments break some of the Si-H bonds and the resulting dangling Si bonds increase the moisture absorption. Meanwhile, NH3 plasma treatments reduce the leakage current by passivating the Si dangling bond and forming silicon nitride. The absorption of moisture and/or the formation of SiNx result in high dielectric constant of HSQ after prolonged NH3 plasma bombardment. The dielectric constant of HSQ decreases and then increases with the increase of NH3 plasma treatment time and a minimum dielectric constant of 2.2 is obtained after 50 s NH3 plasma treatment at 200 W. Among various specimens in this study, the smallest insertion loss is 1.97 dB/mm at 20 GHz for the 400 degrees C-annealed Cu/Ta/HSQ (NH3-plasma-treated for 50 s). Appropriate NH3-plasma bombardment helps to form a thin SiNx barrier layer which prevents the diffusion of oxygen without increasing the dielectric constant of the Cu-HSQ interconnect system. The leakage currents versus electric field characteristics suggest that a Schottky emission dominate conduction mechanism. (c) 2007 Elsevier B.V. All rights reserved.
URI: http://dx.doi.org/10.1016/j.mee.2006.12.010
http://hdl.handle.net/11536/10939
ISSN: 0167-9317
DOI: 10.1016/j.mee.2006.12.010
期刊: MICROELECTRONIC ENGINEERING
Volume: 84
Issue: 4
起始頁: 646
結束頁: 652
顯示於類別:期刊論文


文件中的檔案:

  1. 000245613600016.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。