完整後設資料紀錄
DC 欄位語言
dc.contributor.authorYang, SYen_US
dc.contributor.authorYeh, HDen_US
dc.contributor.authorChiu, PYen_US
dc.date.accessioned2014-12-08T15:16:34Z-
dc.date.available2014-12-08T15:16:34Z-
dc.date.issued2006-05-19en_US
dc.identifier.issn0043-1397en_US
dc.identifier.urihttp://dx.doi.org/10.1029/2004WR003889en_US
dc.identifier.urihttp://hdl.handle.net/11536/12240-
dc.description.abstract[ 1] An analytical model for the constant flux pumping test is developed in a radial confined aquifer system with a partially penetrating well. The Laplace domain solution is derived by the application of the Laplace transforms with respect to time and the finite Fourier cosine transforms with respect to the vertical coordinates. A time domain solution is obtained using the inverse Laplace transforms, convolution theorem, and Bromwich integral method. The effect of partial penetration is apparent if the test well is completed with a short screen. An aquifer thickness 100 times larger than the screen length of the well can be considered as infinite. This solution can be used to investigate the effects of screen length and location on the drawdown distribution in a radial confined aquifer system and to produce type curves for the estimation of aquifer parameters with field pumping drawdown data.en_US
dc.language.isoen_USen_US
dc.titleA closed form solution for constant flux pumping in a well under partial penetration conditionen_US
dc.typeArticleen_US
dc.identifier.doi10.1029/2004WR003889en_US
dc.identifier.journalWATER RESOURCES RESEARCHen_US
dc.citation.volume42en_US
dc.citation.issue5en_US
dc.citation.epageen_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000238016700001-
dc.citation.woscount9-
顯示於類別:期刊論文


文件中的檔案:

  1. 000238016700001.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。