完整後設資料紀錄
DC 欄位語言
dc.contributor.authorHuang, Ren-Youen_US
dc.contributor.authorDung, Lan-Rongen_US
dc.date.accessioned2019-04-03T06:44:33Z-
dc.date.available2019-04-03T06:44:33Z-
dc.date.issued2016-01-29en_US
dc.identifier.issn1475-925Xen_US
dc.identifier.urihttp://dx.doi.org/10.1186/s12938-016-0127-8en_US
dc.identifier.urihttp://hdl.handle.net/11536/129653-
dc.description.abstractBackground: The cardiac parameters, such as heart rate (HR) and heart rate variability (HRV), are very important physiological data for daily healthcare. Recently, the camera-based photoplethysmography techniques have been proposed for HR measurement. These techniques allow us to estimate the HR contactlessly with low-cost camera. However, the previous works showed limit success for estimating HRV because the R-R intervals, the primary data for HRV calculation, are sensitive to noise and artifacts. Methods: This paper proposed a non-contact method to extract the blood volume pulse signal using a chrominance-based method followed by a proposed CWT-based denoising technique. The R-R intervals can then be obtained by finding the peaks in the denoised signal. In this paper, we taped 12 video clips using the frontal camera of a smart phone with different scenarios to make comparisons among our method and the other alternatives using the absolute errors between the estimated HRV metrics and the ones obtained by an ECG-accurate chest band. Results: As shown in experiments, our algorithm can greatly reduce absolute errors of HRV metrics comparing with the related works using RGB color signals. The mean of absolute errors of HRV metrics from our method is only 3.53 ms for the static-subject video clips. Conclusions: The proposed camera-based method is able to produce reliable HRV metrics which are close to the ones measured by contact devices under different conditions. Thus, our method can be used for remote health monitoring in a convenient and comfortable way.en_US
dc.language.isoen_USen_US
dc.subjectCardiac physiologyen_US
dc.subjectNon-contact photoplethysmographyen_US
dc.subjectBlood volume pulseen_US
dc.subjectHeart rate variabilityen_US
dc.titleMeasurement of heart rate variability using off-the-shelf smart phonesen_US
dc.typeArticleen_US
dc.identifier.doi10.1186/s12938-016-0127-8en_US
dc.identifier.journalBIOMEDICAL ENGINEERING ONLINEen_US
dc.citation.volume15en_US
dc.citation.spage0en_US
dc.citation.epage0en_US
dc.contributor.department電機工程學系zh_TW
dc.contributor.department電控工程研究所zh_TW
dc.contributor.departmentDepartment of Electrical and Computer Engineeringen_US
dc.contributor.departmentInstitute of Electrical and Control Engineeringen_US
dc.identifier.wosnumberWOS:000368874500001en_US
dc.citation.woscount8en_US
顯示於類別:期刊論文


文件中的檔案:

  1. d51b7d3a213017eb744b7d8df9be9f31.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。