Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Guo, Jingchun | en_US |
dc.contributor.author | Oshikiri, Tomoya | en_US |
dc.contributor.author | Ueno, Kosei | en_US |
dc.contributor.author | Shi, Xu | en_US |
dc.contributor.author | Misawa, Hiroaki | en_US |
dc.date.accessioned | 2017-04-21T06:56:34Z | - |
dc.date.available | 2017-04-21T06:56:34Z | - |
dc.date.issued | 2017-03-08 | en_US |
dc.identifier.issn | 0003-2670 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.aca.2016.12.025 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/133137 | - |
dc.description.abstract | We developed a localized surface plasmon-induced visible light-responsive photoelectrochemical (PEC) biosensor using a titanium dioxide (TiO2) photoelectrode loaded with gold nanoislands (AuNIs) for in situ real-time measurement of biotin-streptavidin association. As a proof of concept, self-assembled thiol-terminated biotin molecules bound on a AuNls/TiO2 photoelectrode were successfully utilized to explore the photocurrent response to streptavidin-modified gold nanoparticle (STA-AuNP) solutions. This plasmon-induced PEC biosensor is simple and easy to miniaturize. Additionally, the PEC biosensor achieves highly sensitive measurements under only visible light irradiation and prevents the UV-induced damage of samples. Furthermore, a novel approach has been proposed to realize the real-time monitoring of biotin-STA binding affinities and kinetics by analyzing the PEC sensing characteristics. This PEC biosensor and novel analysis method could provide a new approach for the specific electrical detection and real-time kinetic measurements for clinical diagnostics and drug development. (C) 2016 The Authors. Published by Elsevier B.V. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Photoelectrochemical biosensor | en_US |
dc.subject | Localized surface plasmon | en_US |
dc.subject | Kinetic analysis | en_US |
dc.subject | Visible light-response | en_US |
dc.title | Plasmon-induced photoelectrochemical biosensor for in situ real-time measurement of biotin-streptavidin binding kinetics under visible light irradiation | en_US |
dc.identifier.doi | 10.1016/j.aca.2016.12.025 | en_US |
dc.identifier.journal | ANALYTICA CHIMICA ACTA | en_US |
dc.citation.volume | 957 | en_US |
dc.citation.spage | 70 | en_US |
dc.citation.epage | 75 | en_US |
dc.contributor.department | 應用化學系 | zh_TW |
dc.contributor.department | 應用化學系分子科學碩博班 | zh_TW |
dc.contributor.department | Department of Applied Chemistry | en_US |
dc.contributor.department | Institute of Molecular science | en_US |
dc.identifier.wosnumber | WOS:000393252900009 | en_US |
Appears in Collections: | Articles |