Dye-liquid-crystal-based biosensing for quantitative protein assay

檔案

本條目沒有附加檔案。

至出版者網站查看(DOI) ›

日期

2018-03-01

類型

期刊名稱

DYES AND PIGMENTS

卷期與頁次

第 150 卷,頁 73–78

ISSN

0143-7208

語言

英文

摘要

Dye liquid crystals (DLCs) have been extensively investigated in the field of liquid crystal display, but their potential in biosensing has not been explored. To provide insights into the potential of DLCs as a means of biosensing material, a DLC-based biosensor was developed for protein detection and quantitation. Unlike dye doped LCs, the DLC used in this study contains an azobenzene LC molecule chemically modified with two azo groups as chromophores, enabling the DLC to exhibit unique optical anisotropy and dichroic absorption at 470 rim, which were exploited in the quantitation of bovine serum albumin (BSA). The change in orientation of DLC molecules from the homeotropic to a disrupted state by BSA immobilized on the aligning-layer surface was evaluated in terms of the relative loss in transmittance, expressed by the standard parameter S%, due to the absorption as well as scattering of light. The DLC-based protein assay was capable of determining the BSA concentration, with which S% varied linearly between 1 mu g/ml and 7.5 mu g/ml. When the DLC molecules were reoriented from a BSA-disrupted state to the homeotropic alignment by an externally applied electric field, a linear correlation between S% and BSA concentration could be also derived from the voltage transmittance plots. The unique electro-optical properties of the intrinsically dichroic DLC are promising toward the development of a simple and reliable sensing platform for the quantitative analysis of biomolecules.

所屬典藏

期刊論文
顯示完整詮釋資料 統計資料

引用此條目

Wu, P.-C., Karn, A., Lee, M.-J., Lee, W., & Chen, C.-Y. (2018). Dye-liquid-crystal-based biosensing for quantitative protein assay. DYES AND PIGMENTS, 150, 73–78. https://doi.org/10.1016/j.dyepig.2017.11.013

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://ir.lib.nycu.edu.tw/handle/11536/144671