完整後設資料紀錄
DC 欄位語言
dc.contributor.authorAwasthi, Kamleshen_US
dc.contributor.authorNakabayashi, Takakazuen_US
dc.contributor.authorOhta, Nobuhiroen_US
dc.date.accessioned2019-04-03T06:37:12Z-
dc.date.available2019-04-03T06:37:12Z-
dc.date.issued2016-09-01en_US
dc.identifier.issn2470-1343en_US
dc.identifier.urihttp://dx.doi.org/10.1021/acsomega.6b00090en_US
dc.identifier.urihttp://hdl.handle.net/11536/147844-
dc.description.abstractThe fluorescence lifetime of the endogenous fluorophore of reduced nicotinamide adenine dinucleotide (NADH) in HeLa cells is affected by the application of nanosecond pulsed electric fields (nsPEFs). In this study, we found that after nsPEF application, the fluorescence lifetime became longer and then decreased in a stepwise manner upon further application, irrespective of the pulse width in the range of 10-50 ns. This application time dependence of the NADH fluorescence lifetime is very similar to the time-lapse dependence of the NADH fluorescence lifetime following the addition of an apoptosis inducer, staurosporine. These results, as well as the membrane swelling and blebbing after the application of nsPEFs, indicate that apoptosis is also induced by the application of nsPEFs in HeLa cells. In contrast to the lifetime, the fluorescence intensity remarkably depended on the pulse width of the applied nsPEF. When the pulse width was as large as 50 ns, the intensity monotonically increased and was distributed over the entire cell as the application duration became longer. As the pulse width of the applied electric field became smaller, the magnitude of the field-induced increase in NADH fluorescence intensity decreased; the intensity was reduced by the electric field when the pulse width was as small as 10 ns. These results suggest that the mechanism of electric-field-induced apoptosis depends on the pulse width of the applied nsPEF.en_US
dc.language.isoen_USen_US
dc.titleEffects of Nanosecond Pulsed Electric Fields on the Intracellular Function of HeLa Cells As Revealed by NADH Autofluorescence Microscopyen_US
dc.typeArticleen_US
dc.identifier.doi10.1021/acsomega.6b00090en_US
dc.identifier.journalACS OMEGAen_US
dc.citation.volume1en_US
dc.citation.issue3en_US
dc.citation.spage396en_US
dc.citation.epage406en_US
dc.contributor.department應用化學系zh_TW
dc.contributor.department應用化學系分子科學碩博班zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.contributor.departmentInstitute of Molecular scienceen_US
dc.identifier.wosnumberWOS:000391204000010en_US
dc.citation.woscount3en_US
顯示於類別:期刊論文


文件中的檔案:

  1. d2eb0cafd8e9ff00b624000b00b1e6eb.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。