完整後設資料紀錄
DC 欄位語言
dc.contributor.authorMao, Hui-Fenen_US
dc.contributor.authorHuang, Hsing-Poen_US
dc.contributor.authorLu, Tung-Wuen_US
dc.contributor.authorWang, Ting-Mingen_US
dc.contributor.authorWu, Cheng-Huaen_US
dc.contributor.authorHu, Jwu-Shengen_US
dc.date.accessioned2019-04-02T05:59:58Z-
dc.date.available2019-04-02T05:59:58Z-
dc.date.issued2018-10-01en_US
dc.identifier.issn0003-9993en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.apmr.2018.04.004en_US
dc.identifier.urihttp://hdl.handle.net/11536/148283-
dc.description.abstractObjective: To quantify the effects of initial hip angle and angular hip velocity settings of a lower-limb wearable robotic exoskeleton (WRE) on the balance control and mechanical energy requirements in patients with paraplegic spinal cord injuries (SCIs) during WRE-assisted sit-to-stand (STS). Design: Observational, cross-sectional study. Setting: A university hospital gait laboratory with an 8-camera motion analysis system, 3 forceplates, a pair of instrumented crutches, and a WRE. Participants: Patients (N = 12) with paraplegic SCI. Interventions: Not applicable. Main Outcome Measures: The inclination angle (IA) of the body's center of mass (COM) relative to the center of pressure (COP), and the rate of change of IA (RCIA) for balance control, and the mechanical energy and forward COM momentum before and after seat-off for energetics during WRE-assisted STS were compared between conditions with 2 initial hip angles (105 degrees and 115 degrees) and 3 initial hip angular velocities (800, 1000, 1200 rpm). Results: No interactions between the main factors (ie, initial hip angle vs angular velocity) were found for any of the calculated variables. Greater initial hip angle helped the patients with SCI move the body forward with increased COM momentum but reduced RCIA (P<.05). With increasing initial angular hip velocity, the IA and RCIA after seat-off (P<.05) increased linearly while total mechanical energy reduced linearly (P<.05). Conclusions: The current results suggest that a greater initial hip angle with smaller initial angular velocity may provide a favorable compromise between momentum transfer and balance of the body for people with SCI during WRE-assisted STS. The current data will be helpful for improving the design and clinical use of the WRE. (C) 2018 by the American Congress of Rehabilitation Medicineen_US
dc.language.isoen_USen_US
dc.subjectExoskeleton deviceen_US
dc.subjectPostural balanceen_US
dc.subjectRehabilitationen_US
dc.subjectSpinal cord injuryen_US
dc.titleBalance Control and Energetics of Powered Exoskeleton-Assisted Sit-to-Stand Movement in Individuals With Paraplegic Spinal Cord Injuryen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.apmr.2018.04.004en_US
dc.identifier.journalARCHIVES OF PHYSICAL MEDICINE AND REHABILITATIONen_US
dc.citation.volume99en_US
dc.citation.spage1982en_US
dc.citation.epage1990en_US
dc.contributor.department電控工程研究所zh_TW
dc.contributor.departmentInstitute of Electrical and Control Engineeringen_US
dc.identifier.wosnumberWOS:000447245600005en_US
dc.citation.woscount0en_US
顯示於類別:期刊論文