dc.description.abstractThe energy consumptions of data centers are increasing dramatically and cooling systems using for controlling the operating temperature usually consume more than half of these energy. Thus, effective strategies on thermal management in data centers may have benefit on energy savings. In order to improve the power usage effectiveness (PUE) of data centers, the effects of air supply flowrate by computer room air handler (CRAH), intake flowrate of rack cooling fans, air supply grilles and heat load distribution on the cooling performance of a typical small container data center having overhead air supply system are investigated in this paper. The rack cooling index (RCI) and supply heat index (SHI) are incorporated to evaluate the local and average cooling performance of data racks. It is found that the intake flowrate of rack cooling fans plays dominant role, which is suggested to be greater than the air supply flowrate in normal operation. Meanwhile, the volumetric flowrate distribution of grilles is studied. The additional front grille before entering the cold aisle may improve the RCI and SHI of front rack (rack A), in which severe hot-air recirculation may occur in typical operation. Conversely, additional rear grille at the exit of cold aisle has negative effect on cooling performance of the last rack (rack E). Based on the measurement of local temperature distribution, the non-uniform heat load distribution in racks is proposed. Result shows that the RCI can be improved to 64% if more power is placed at lower half part, which is eligible for energy saving. However, the non-uniform heat load distribution shows limited improvement on the rear rack (rack E).en_US
dc.language.isoen_USen_US
dc.subjectContainer data centeren_US
dc.subjectCooling performanceen_US
dc.subjectRecirculationen_US
dc.subjectRack cooling indexen_US
dc.subjectSupplied heat indexen_US
dc.titleExperimental investigation on thermal management for small container data centeren_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.jobe.2018.10.031en_US
dc.identifier.journalJOURNAL OF BUILDING ENGINEERINGen_US
dc.citation.volume21en_US
dc.citation.spage317en_US
dc.citation.epage327en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000451757200030en_US
dc.citation.woscount0en_US
顯示於類別:期刊論文