dc.description.abstractPool boiling data for binary mixtures of R-22/R-124 on plain tubes are reported at reduced pressures of 0.1, 0.15, and 0.2. Significant reductions of heat transfer coefficients for mixtures are found as compared to pure refrigerant, and the reduction of heat transfer coefficient is especially pronounced in the vicinity of the pore component. This phenomenon is strongly related to the nonlinear variation of physical properties of liquid viscosity and latent heat of the mixtures. The available empirical and semiempirical correlations developed for mixtures are compared with the present data. In addition, a correlation based on the present R-22/R-124 experimental data is proposed. This correlation not only predicts the deterioration of heat transfer coefficients for the present data with success but also predicts the experimental data from other investigators with reasonably good accuracy.en_US
dc.language.isoen_USen_US
dc.titleInvestigations of pool boiling heat transfer of binary refrigerant mixturesen_US
dc.typeArticleen_US
dc.identifier.doi10.1080/01457639708939902en_US
dc.identifier.journalHEAT TRANSFER ENGINEERINGen_US
dc.citation.volume18en_US
dc.citation.spage61en_US
dc.citation.epage72en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:A1997XR31000005en_US
dc.citation.woscount9en_US
Appears in Collections:Articles