標題: A Versatile Method to Enhance the Operational Current of Air-Stable Organic Gas Sensor for Monitoring of Breath Ammonia in Hemodialysis Patients
作者: Yu, Shang-Yu
Tung, Tin-Wei
Yang, Hong-Yu
Chen, Guan-Yu
Shih, Che-Chi
Lee, Yu-Chih
Chen, Chang-Chiang
Zan, Hsiao-Wen
Meng, Hsin-Fei
Lu, Chia-Jung
Wang, Chien-Lung
Jian, Wen-Bin
Soppera, Olivier
生物科技學系
電子物理學系
應用化學系
物理研究所
光電工程學系
Department of Biological Science and Technology
Department of Electrophysics
Department of Applied Chemistry
Institute of Physics
Department of Photonics
關鍵字: ammonia;breath;current enhancement;gas sensor;hemodialysis;POC device;stable performance
公開日期: 1-四月-2019
摘要: Point-of-care (POC) application for monitoring of breath ammonia (BA) in hemodialysis (HD) patients has emerged as a promising noninvasive health monitoring approach. In this context, many organic gas sensors have been reported for BA detection. However, one of the major challenges for its integration with affordable household POC application is to achieve stable performance for accuracy and high operational current at low voltage for low-cost read-out circuitry. Herein, we exploited the stability of the Donor Acceptor polymer on the cylindrical nanopore structure to realize the sensors with a high sensitivity and stability. Then, we proposed a double active layer (DL) strategy that exploits an ultrathin layer of Poly(3-hexylthiophene-2,5-diyl) (P3HT) to serve as a work function buffer to enhance the operational current. The DL sensor exhibits a sustainable operational current of microampere level and a stable sensing response even with the presence of P3HT layer. This effect is carefully examined with different aspects, including vertical composition profile of DL configuration, lifetime testing on different sensing layer, morphological analysis, and the versatility of the DL strategy. Finally, we utilize the DL sensor to conduct a tracing of BA concentration in two HD patients before and after HD, and correlate it with the blood urea nitrogen (BUN) levels. A good correlation coefficient of 0.96 is achieved. Moreover, the feasibility of DL sensor integrated into a low-cost circuitry was also verified. The results demonstrate the potential of this DL strategy to be used to integrate organic sensor for affordable household POC devices.
URI: http://dx.doi.org/10.1021/acssensors.9b00223
http://hdl.handle.net/11536/152297
ISSN: 2379-3694
DOI: 10.1021/acssensors.9b00223
期刊: ACS SENSORS
Volume: 4
Issue: 4
起始頁: 1023
結束頁: 1031
顯示於類別:期刊論文