完整後設資料紀錄
DC 欄位語言
dc.contributor.authorWu, Tsung-Hsienen_US
dc.contributor.authorPan, Jui-wenen_US
dc.date.accessioned2019-12-13T01:12:24Z-
dc.date.available2019-12-13T01:12:24Z-
dc.date.issued2020-01-15en_US
dc.identifier.issn0030-4018en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.optcom.2019.124453en_US
dc.identifier.urihttp://hdl.handle.net/11536/153247-
dc.description.abstractAn optical design for an immersive head-mounted display (HMD) with a liquid lens is described. This design combines the liquid lens with an immersive HMD system to improve the image quality for myopic and hyperopic users. A penta-prism is also incorporated and used to change the direction of the optical path to improve any optical aberration caused by the gravity effect. This immersive head-mounted display has a field of view of 14.9 degrees, focal length of 47.78 mm, and f-number of 5.97 with an exit pupil diameter of 8 mm, eye relief of 15 mm. The value of the MTF is above 0.9 at 3.3 lp/mm.en_US
dc.language.isoen_USen_US
dc.titleAn immersive head-mounted display with a liquid lensen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.optcom.2019.124453en_US
dc.identifier.journalOPTICS COMMUNICATIONSen_US
dc.citation.volume455en_US
dc.citation.spage0en_US
dc.citation.epage0en_US
dc.contributor.department光電系統研究所zh_TW
dc.contributor.department影像與生醫光電研究所zh_TW
dc.contributor.departmentInstitute of Photonic Systemen_US
dc.contributor.departmentInstitute of Imaging and Biomedical Photonicsen_US
dc.identifier.wosnumberWOS:000495589700005en_US
dc.citation.woscount0en_US
顯示於類別:期刊論文