Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lo, Cheng-Chan | en_US |
dc.contributor.author | Tsai, Kai-Jow | en_US |
dc.contributor.author | Chen, Shih-Hao | en_US |
dc.contributor.author | Zhong, Zheng-Cheng | en_US |
dc.contributor.author | Hung, Chinghua | en_US |
dc.date.accessioned | 2014-12-08T15:21:40Z | - |
dc.date.available | 2014-12-08T15:21:40Z | - |
dc.date.issued | 2011 | en_US |
dc.identifier.issn | 1025-5842 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/15390 | - |
dc.identifier.uri | http://dx.doi.org/10.1080/10255842.2010.502894 | en_US |
dc.description.abstract | The Coflex device may provide stability to the surgical segment in extension but does not restore stability in other motion. Recently, a modified version called the Coflex rivet has been developed. The effects of Coflex and Coflex rivet implantation on the adjacent segments are still not clear; therefore, the purpose of this study was to investigate the biomechanical differences between Coflex and Coflex rivet implantation by using finite element analyses. The results show that the Coflex implantation can provide stability in extension, lateral bending, and axial rotation at the surgical segment, and it had no influence at adjacent segments except for extension. The Coflex rivet implantation can provide stability in all motions and reduce disc annulus stress at the surgical segment. Therefore, the higher range of motion and stress induced by the Coflex rivet at both adjacent discs may result in adjacent segment degeneration in flexion and extension. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | lumbar spinal stenosis | en_US |
dc.subject | interspinous process device | en_US |
dc.subject | Coflex rivet follower load | en_US |
dc.subject | disc annulus stress | en_US |
dc.subject | finite element analysis | en_US |
dc.title | Biomechanical effect after Coflex and Coflex rivet implantation for segmental instability at surgical and adjacent segments: a finite element analysis | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1080/10255842.2010.502894 | en_US |
dc.identifier.journal | COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING | en_US |
dc.citation.volume | 14 | en_US |
dc.citation.issue | 11 | en_US |
dc.citation.spage | 969 | en_US |
dc.citation.epage | 978 | en_US |
dc.contributor.department | 機械工程學系 | zh_TW |
dc.contributor.department | Department of Mechanical Engineering | en_US |
dc.identifier.wosnumber | WOS:000299434200005 | - |
dc.citation.woscount | 1 | - |
Appears in Collections: | Articles |
Files in This Item:
If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.