完整後設資料紀錄
DC 欄位語言
dc.contributor.authorHung, Huan-Yien_US
dc.contributor.authorLu, Chien-Weien_US
dc.contributor.authorLee, Cheng-Yuen_US
dc.contributor.authorHsu, Chain-Shuen_US
dc.contributor.authorHsieh, You-Zungen_US
dc.date.accessioned2014-12-08T15:28:11Z-
dc.date.available2014-12-08T15:28:11Z-
dc.date.issued2012-11-01en_US
dc.identifier.issn1759-9660en_US
dc.identifier.urihttp://dx.doi.org/10.1039/c2ay25627den_US
dc.identifier.urihttp://hdl.handle.net/11536/20400-
dc.description.abstractWe have developed a method, using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS), to directly analyze metal ion impurities in liquid crystals (LCs). From measurements of resistivity, a commonly used technique for quality control of liquid crystal display (LCD) cells, we found that the resistivities of the LCs decreased significantly upon progressing through the different stages of the LCD cell manufacturing process. We determined the levels of metal ion impurities in the LCs through direct loading of diluted LC samples into the HR-ICP-MS system at a steady flow rate. Solutions featuring LC contents of 10% (v/v) were formed by dissolving each LC in isopropanol (IPA) containing acetone as a modifier. We quantified the trace metal ion impurities in the LC samples using a certified standard of metal ions diluted in IPA (external calibration) without the need for digestion pretreatment. Next, we compared the levels of metal ion impurities with the resistivities of the LCs at the different stages of the LCD cell manufacturing process. We confirmed that the resistivities of the LCs decreased as the total levels of metal ion impurities in the LCs increased. The total content of metal ion impurities added into the LC was higher in the siphoning process than in the one-drop filling process during the fabrication of LCD cells. The HR-ICP-MS method could, therefore, be used to directly measure metal ion impurities in LCs during the LCD cell manufacturing process, potentially replacing resistivity measurements of LCs as a means of quality control. We suggest setting 1400 ng L-1 as the limit of the total metal ion concentration in LCs used for LCD cell manufacturing. We used the HR-ICP-MS method to analyze a stained LCD panel to confirm that the content of metal ion impurities was indeed significantly greater in the stained area of the defected LCD. HR-ICP-MS appears to be a promising technique for the direct and effective analyses of metal ion impurities in LCs.en_US
dc.language.isoen_USen_US
dc.titleAnalysis of metal ion impurities in liquid crystals using high resolution inductively coupled plasma mass spectrometryen_US
dc.typeArticleen_US
dc.identifier.doi10.1039/c2ay25627den_US
dc.identifier.journalANALYTICAL METHODSen_US
dc.citation.volume4en_US
dc.citation.issue11en_US
dc.citation.spage3631en_US
dc.citation.epage3637en_US
dc.contributor.department應用化學系zh_TW
dc.contributor.department電子工程學系及電子研究所zh_TW
dc.contributor.departmentDepartment of Applied Chemistryen_US
dc.contributor.departmentDepartment of Electronics Engineering and Institute of Electronicsen_US
dc.identifier.wosnumberWOS:000310281700021-
dc.citation.woscount3-