完整後設資料紀錄
DC 欄位語言
dc.contributor.authorLee, Yuh-Renen_US
dc.contributor.authorKuo, Chi-Ronen_US
dc.contributor.authorWang, Chi-Chuanen_US
dc.date.accessioned2014-12-08T15:29:18Z-
dc.date.available2014-12-08T15:29:18Z-
dc.date.issued2012-12-01en_US
dc.identifier.issn0360-5442en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.energy.2012.10.029en_US
dc.identifier.urihttp://hdl.handle.net/11536/21096-
dc.description.abstractThis study examines the transient responses of a 50 kW ORC (Organic Rankine Cycle) system subject to change of the water coolant in the condenser with R-245fa as the working fluid. With a moderate increase or decrease of water coolant flow rate, all the major quantities such as the output power, condensing pressure, evaporation pressure show mild transition. The mass flow rate of the R-245fa remains roughly the same during the transient. For a sharp rise of the water coolant flow rate, the ORC system undergoes a rather unusual behavior. The output power is first slightly increased, followed by a sharp decline to barely any output power and remains there until the end of the transient. The output power increased back right after the transient and exceeded its original state. There is almost no R-245fa mass flow rate during the power outage period. Yet the evaporation pressure also experienced a gigantic falloff during the transient period. This peculiar surge phenomenon is related to tremendous change of the total void when condensation takes place that momentarily reduces the R-245fa mass flow rate. The surge effect caused by the water coolant is associated with the rate of variation in the overall heat transfer coefficient. (C) 2012 Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectOrganic Rankine cycleen_US
dc.subjectTransient responseen_US
dc.subjectCondenseren_US
dc.titleTransient response of a 50 kW organic Rankine cycle systemen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.energy.2012.10.029en_US
dc.identifier.journalENERGYen_US
dc.citation.volume48en_US
dc.citation.issue1en_US
dc.citation.spage532en_US
dc.citation.epage538en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000313461800061-
dc.citation.woscount5-
顯示於類別:期刊論文


文件中的檔案:

  1. 000313461800061.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。