Title: Perturbation On-Time (POT) Technique in Power Factor Correction (PFC) Controller for Low Total Harmonic Distortion and High Power Factor
Authors: Tsai, Jen-Chieh
Chen, Chi-Lin
Chen, Yi-Ting
Ni, Chia-Lung
Chen, Chun-Yen
Chen, Ke-Horng
電控工程研究所
Institute of Electrical and Control Engineering
Keywords: Inhibit time (IT) control;nonnegative-voltage zero current detector (NNV-ZCD);perturbation on time (POT);power factor correction (PFC);ultrahigh voltage (UHV)
Issue Date: 1-Jan-2013
Abstract: The proposed perturbation on-time technique suppresses total harmonic distortion (THD) and, thus, improves the power factor in the power factor correction (PFC) controller. Besides, the adaptive control of the minimum off time by the proposed inhibit time control can improve efficiency even at low ac input voltage. Therefore, highly integrated PFC converter fabricated in the TSMC 800-V ultrahigh voltage process can achieve low THD of 6%, high PF of 99%, and high efficiency of 95% at the output power of 90 W.
URI: http://dx.doi.org/10.1109/TPEL.2012.2195333
http://hdl.handle.net/11536/21280
ISSN: 0885-8993
DOI: 10.1109/TPEL.2012.2195333
Journal: IEEE TRANSACTIONS ON POWER ELECTRONICS
Volume: 28
Issue: 1
Begin Page: 199
End Page: 212