完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChen, Yung-Changen_US
dc.contributor.authorHsu, Wei-Hungen_US
dc.contributor.authorCheng, Shih-Hsienen_US
dc.contributor.authorCheng, Yu-Tingen_US
dc.date.accessioned2014-12-08T15:30:11Z-
dc.date.available2014-12-08T15:30:11Z-
dc.date.issued2012en_US
dc.identifier.isbn978-1-4577-1766-6en_US
dc.identifier.issn1930-0395en_US
dc.identifier.urihttp://hdl.handle.net/11536/21625-
dc.description.abstractThis paper presents a sensitivity enhancement scheme for the flexible inductive coil tag used for the current detection of household two-wire power lines. Experimental results show that the inductive coil tag can exhibit a larger induced voltage by the introduction of the magnetic C-clamp stripes that can guide and concentrate the magnetic flux in the center area of the inductive coil. For a 30-turns inductive coil, the incorporation of a 2 mu m thick Ni and NiFe C-clamp stripes with 14.5 mm in length and similar to 20 mu m in height onto the coil can provide 15.5% and 37.2% sensitivity enhancement, respectively, for detecting 1A, 60Hz electric current flow in a SPT-2 16AWG power line.en_US
dc.language.isoen_USen_US
dc.titleSensitivity Enhancement of the Flexible Inductive Coil Tag Using Magnetic C-Clamp Stripes for the Current Detection of Household Two-Wire Power Linesen_US
dc.typeProceedings Paperen_US
dc.identifier.journal2012 IEEE SENSORS PROCEEDINGSen_US
dc.citation.spage2050en_US
dc.citation.epage2053en_US
dc.contributor.department電子工程學系及電子研究所zh_TW
dc.contributor.departmentDepartment of Electronics Engineering and Institute of Electronicsen_US
dc.identifier.wosnumberWOS:000315671100490-
顯示於類別:會議論文