完整後設資料紀錄
DC 欄位語言
dc.contributor.authorChang, Y. C.en_US
dc.contributor.authorYeh, H. D.en_US
dc.contributor.authorWang, C. T.en_US
dc.date.accessioned2014-12-08T15:30:18Z-
dc.date.available2014-12-08T15:30:18Z-
dc.date.issued2013-04-01en_US
dc.identifier.issn0262-6667en_US
dc.identifier.urihttp://dx.doi.org/10.1080/02626667.2012.755534en_US
dc.identifier.urihttp://hdl.handle.net/11536/21691-
dc.description.abstractPapadopulos and Cooper's (PC) solution can be used to describe the drawdown resulting from pumping with a constant rate at a large-diameter well. However, this solution is too complicated to be accurately evaluated due to the oscillatory nature of the Bessel functions. The PC approach resulted in tabulated values of dimensionless drawdown at the well with an accuracy of four or fewer digits for selected values of dimensionless storage coefficient versus dimensionless time. Some researchers have fitted the tabulated values with interpolation formulas that are easy to use in engineering applications. Those formulas may be more accurate if the tabulated values are computed with greater accuracy. In this study, we propose an efficient numerical procedure, including a root search scheme, to find the roots of the integrand, Gaussian quadrature for numerical integration, and Shanks transform to accelerate convergence of infinite series. The proposed procedure can evaluate the dimensionless drawdown with greater accuracy and is useful in practice if there is a need for high accuracy for the observation either at the well or in the aquifer at some distance from the pumping well Editor D. Koutsoyiannis Citation Chang, Y.C., Yeh, H.D., and Wang, C.T., 2013. Improvement on the estimation of constant-rate drawdown in large-diameter wells. Hydrological Sciences Journal, 58 (3), 716727.en_US
dc.language.isoen_USen_US
dc.subjectconstant-rate pumpingen_US
dc.subjectlarge-diameter wellen_US
dc.subjectdrawdownen_US
dc.subjectaquifersen_US
dc.subjectwellsen_US
dc.subjectnumerical approachen_US
dc.titleImprovement on the estimation of constant-rate drawdown in large-diameter wellsen_US
dc.typeArticleen_US
dc.identifier.doi10.1080/02626667.2012.755534en_US
dc.identifier.journalHYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUESen_US
dc.citation.volume58en_US
dc.citation.issue3en_US
dc.citation.spage716en_US
dc.citation.epage727en_US
dc.contributor.department環境工程研究所zh_TW
dc.contributor.departmentInstitute of Environmental Engineeringen_US
dc.identifier.wosnumberWOS:000317838400015-
dc.citation.woscount0-
顯示於類別:期刊論文


文件中的檔案:

  1. 000317838400015.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。