Full metadata record
DC FieldValueLanguage
dc.contributor.authorSong, Yu-Linen_US
dc.contributor.authorJian, Jhong-Tingen_US
dc.contributor.authorChen, Wei-Zenen_US
dc.contributor.authorShih, Chih-Huaen_US
dc.contributor.authorChou, Yuan-Fangen_US
dc.contributor.authorLiu, Tien-Chenen_US
dc.contributor.authorLee, Chia-Foneen_US
dc.date.accessioned2014-12-08T15:32:14Z-
dc.date.available2014-12-08T15:32:14Z-
dc.date.issued2013-12-01en_US
dc.identifier.issn0003-682Xen_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.apacoust.2013.06.014en_US
dc.identifier.urihttp://hdl.handle.net/11536/22671-
dc.description.abstractA non-surgical, direct driving hearing device with an actuator placed on the tympanic membrane was designed, fabricated and tested. The actuator consisted of two photodiodes, an aluminum ring, two neodymium iron permanent magnets, two opposing wound coils, a latex membrane and a Provil Novo (TM) membrane. The transducer coupled to the ear drum-utilizing photodiodes and permanent magnets on the motive components could eliminate the need for electrical connections to the moving components. An optic probe was designed to allow sound and light signals to enter the ear canal. By using opto-electromagnetic coupling, the developed hearing device could transmit information over a distance without using cables. The wireless actuator was achieved by two configurations: in one, two light emitting diodes were used for carrying the input signals, and in the other, the corresponding photodiodes were used for receiving the light signals and generating the currents in the actuator. The wireless actuator was designed to use light to carry energy and transmit the signals; thus, the occlusion effect created by traditional ear molds could be avoided. Finally, the wireless actuator was fabricated and tested with a laser Doppler vibrometer. The actuator showed displacements of vibration between 30-0.2 nm and from 400 Hz to 7 kHz with reduced vibration at higher frequencies. The gain of the actuator with 120 mu A on the umbo displacement was approximately 3-13 dB from 400 to1500 Hz and decreased to 6 dB between 1500 Hz to 3 kHz and down to -1 to -6 dB above 3 kHz. Distortions of the umbo vibration amplitude were approximately -1 to -10 dB across frequencies. The results suggest that light can transmit the sound signal remotely and that adequate amplification can be achieved by this actuator. The reduced amplitude above 3 kHz was a consequence of the mass effect of the actuator, which should be miniaturized in the future. Crown Copyright (c) 2013 Published by Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectHearing aidsen_US
dc.subjectWirelessen_US
dc.subjectActuatoren_US
dc.subjectElectromagneticen_US
dc.subjectFinite element analysisen_US
dc.titleThe development of a non-surgical direct drive hearing device with a wireless actuator coupled to the tympanic membraneen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.apacoust.2013.06.014en_US
dc.identifier.journalAPPLIED ACOUSTICSen_US
dc.citation.volume74en_US
dc.citation.issue12en_US
dc.citation.spage1511en_US
dc.citation.epage1518en_US
dc.contributor.department電子工程學系及電子研究所zh_TW
dc.contributor.departmentDepartment of Electronics Engineering and Institute of Electronicsen_US
dc.identifier.wosnumberWOS:000324227100025-
dc.citation.woscount1-
Appears in Collections:Articles


Files in This Item:

  1. 000324227100025.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.