dc.description.abstractThis paper deals with the damage assessment for isolators of base-isolated building systems considering the torsion-coupling (TC) effect by establishing damage indices. The damage indices can indicate the reduction in lateral stiffness of the isolator story as explicit formulas in terms of modal parameters. In addition, the damage location, expressed in terms of the estimated damage index and eccentricities before and after damage, is also presented. Numerical analysis shows that the proposed algorithms are applicable for general base-isolated multi-story TC buildings. A procedure from the analysis of seismic response to the implementation of damage indices is demonstrated by using a numerical case. A system identification technique is employed to extract modal parameters from seismic responses of a building. Results show that the proposed indices are capable of detecting the occurrence of damage and preliminarily estimating the location of damaged isolator.en_US
dc.language.isoen_USen_US
dc.subjectbase isolationen_US
dc.subjecttorsion-coupling effecten_US
dc.subjectdamage detectionen_US
dc.subjectdamage locatingen_US
dc.titleDamage identification of isolators in base-isolated torsionally coupled buildingsen_US
dc.typeArticleen_US
dc.identifier.journalSMART STRUCTURES AND SYSTEMSen_US
dc.citation.volume11en_US
dc.citation.issue4en_US
dc.citation.spage387en_US
dc.citation.epage410en_US
dc.contributor.department土木工程學系zh_TW
dc.contributor.departmentDepartment of Civil Engineeringen_US
dc.identifier.wosnumberWOS:000324873900004-
dc.citation.woscount0-