dc.description.abstractIt is in general challenging to characterize planar mechanical properties of extremely soft tissues such as cell-seeded collagen gels. One of the difficulties is related to premature failure of specimens. This issue may be resolved by employing fillets on stress-concentrated spots of the specimen. The existence of fillets, however, complicates the estimation of stress at the center of the specimen where stiffness data are collected. In this study, cruciform rubber specimens with two types of fillets (general vs. cut-in fillets) at the intersections of perpendicular arms were prepared and subjected to planar biaxial mechanical testing, aiming at investigating how the fillets affect the estimation of mechanical properties of cruciform specimens. Digital image correlation was used to analyze full-field deformation in the central region of the specimens. Finite element analysis with a Neo-Hookean model was performed to simulate the full-field deformation under the same experimental boundary conditions. The strain distribution for each specimen geometry obtained by finite element analysis was found to be in good agreement with that analyzed by digital image correlation, validating the finite element models. Finite element simulation showed that the greatest value of the maximum principal strain decreased with increasing the fillet radius regardless of the fillet type. Increasing the fillet radius, in general, also reduced the strain field uniformity in the central region. Compared with general fillets, however, the use of cut-in fillets provided greater strain field uniformity given the same fillet radius. Finite element analysis was also used to estimate effective transverse length required to convert tensile force at the boundary to local stress at the center. It was found that the effective transverse length for each specimen geometry remained relatively constant if the specimen was not excessively deformed (i.e., global equibiaxial stretch a parts per thousand currency sign 1.2). We suggest using cut-in fillets at the intersections of perpendicular arms when preparing cruciform specimens for testing extremely soft tissues.en_US
dc.language.isoen_USen_US
dc.subjectPlanar biaxial mechanical testingen_US
dc.subjectSpecimen geometryen_US
dc.subjectFilletsen_US
dc.subjectDigital image correlationen_US
dc.subjectFinite element methoden_US
dc.subjectSoft tissuesen_US
dc.titleInfluence of Specimen Geometry on the Estimation of the Planar Biaxial Mechanical Properties of Cruciform Specimensen_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s11340-013-9826-2en_US
dc.identifier.journalEXPERIMENTAL MECHANICSen_US
dc.citation.volume54en_US
dc.citation.issue4en_US
dc.citation.spage615en_US
dc.citation.epage631en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000333426300009-
dc.citation.woscount0-
顯示於類別:期刊論文


文件中的檔案:

  1. 000333426300009.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。