Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dai, KS | en_US |
dc.contributor.author | Tai, DY | en_US |
dc.contributor.author | Ho, P | en_US |
dc.contributor.author | Chen, CC | en_US |
dc.contributor.author | Peng, WC | en_US |
dc.contributor.author | Chen, ST | en_US |
dc.contributor.author | Hsu, CC | en_US |
dc.contributor.author | Liu, YP | en_US |
dc.contributor.author | Hsieh, HC | en_US |
dc.contributor.author | Yang, CC | en_US |
dc.contributor.author | Tsai, MC | en_US |
dc.contributor.author | Mao, SJT | en_US |
dc.date.accessioned | 2014-12-08T15:37:21Z | - |
dc.date.available | 2014-12-08T15:37:21Z | - |
dc.date.issued | 2004-11-01 | en_US |
dc.identifier.issn | 0009-8981 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1016/j.cccn.2004.06.010 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/25690 | - |
dc.description.abstract | Background: Self-monitoring blood glucose device is an important toot for diabetes patients to efficiently control their blood glucose concentrations. We evaluated the accuracy of EasyTouch glucose monitoring system. Methods: Capillary blood glucose concentrations measured using EasyTouch and the reference values obtained from Yellow Springs Instruments (YSI) 2300 STAT were performed in the Department of Laboratory Medicine, Wei-Gong Memorial Hospital. Results were evaluated using (1) linear regression analysis, (2) Clarke Error Grid analysis, (3) percentage of readings within a defined range of deviation from the reference value, (4) bias plots, and (5) coefficients of variation (CVs) calculated from 60 measurements in series. Results: The window of the 516 EasyTouch readings covered a range from 42 to 555 mg/dl. Linear regression analysis yielded a regression slope 0.9972, intercept 1.899 mg/dl, r(2) 0.9571, and Syx 14.89 mg/dl. A Clarke Error Grid analysis showed 100% of the EasyTouch readings in clinically acceptable zones A and B. Of the EasyTouch readings, 98.3%, 91.9%, 78.3% and 46.9% were found within +/-20%, +/-15%, +/-10%, and +/-5%, respectively, of the reference values. Further analysis showed that the percentage of EasyTouch readings within the defined intervals was similar in three glucose ranges (less than or equal to100, 101-200, and greater than or equal to201 mg/dl). The CVs for the four lots of strips (lot 1 to lot 4) ranged from 3.5 to 5.5%, 2.1 to 4.8%, 1.8 to 3.6%, and 3.0 to 5.7%, respectively. Conclusions: EasyTouch provides high accurate and precise glucose readings over a wide range of glucose concentrations. (C) 2004 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | diabetes mellitus | en_US |
dc.subject | glucose self-monitoring system | en_US |
dc.subject | Clarke Error Grid analysis | en_US |
dc.subject | home testing | en_US |
dc.subject | point-of-care testing | en_US |
dc.title | Accuracy of the EasyTouch blood glucose self-monitoring system: a study of 516 cases | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.1016/j.cccn.2004.06.010 | en_US |
dc.identifier.journal | CLINICA CHIMICA ACTA | en_US |
dc.citation.volume | 349 | en_US |
dc.citation.issue | 1-2 | en_US |
dc.citation.spage | 135 | en_US |
dc.citation.epage | 141 | en_US |
dc.contributor.department | 生物科技學系 | zh_TW |
dc.contributor.department | Department of Biological Science and Technology | en_US |
dc.identifier.wosnumber | WOS:000224673500017 | - |
dc.citation.woscount | 18 | - |