完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Wu, Hung-Shan | en_US |
dc.contributor.author | Hsu, Huai-Yuan | en_US |
dc.contributor.author | Chang, Chia-Chi | en_US |
dc.contributor.author | Hsiao, Tzu-Chien | en_US |
dc.date.accessioned | 2014-12-08T15:38:20Z | - |
dc.date.available | 2014-12-08T15:38:20Z | - |
dc.date.issued | 2010-12-01 | en_US |
dc.identifier.issn | 1016-2372 | en_US |
dc.identifier.uri | http://dx.doi.org/10.4015/S1016237210002201 | en_US |
dc.identifier.uri | http://hdl.handle.net/11536/26252 | - |
dc.description.abstract | The purpose of anesthesia is to maintain a steady state for specific clinical operations. In general, one anesthesiologist utilizes anesthetic drugs and anesthetic skills to make sure the depth of anesthesia (DOA) carefully in proper level such that a patient will not perceive pain during surgical procedure. It is complex to be treated as an art to reduce all sensations, whether it is the sense of pain, touch, temperature, or position. In this paper, utilizing the self-learning and the human-like reasoning ability of neurofuzzy networks, we design the virtual anesthesiologist to accommodate the knowledge and the experience of the real anesthesiologist in anesthetic drug administration. The heart rate and bispectral index are used as the input variables and the bispectral index target value (BIS(target)) heart is treated as output variable. The anesthesia simulator is adopted to verify the virtual anesthesiologist's ability and to explore the patient status of the simulator. The pilot experiments and extended experiments have been carried out. The result showed that the virtual anesthesiologist was able to support the decision making on the maintenance of the patient DOA at BIS(target) 60. | en_US |
dc.language.iso | en_US | en_US |
dc.subject | Neurofuzzy network | en_US |
dc.subject | Virtual anesthesiologist | en_US |
dc.title | USING NEUROFUZZY NETWORKS TO MIMIC ANESTHESIOLOGIST KNOWLEDGE IN DECISION MAKING ON PROPOFOL ADMINISTRATION | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.4015/S1016237210002201 | en_US |
dc.identifier.journal | BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | en_US |
dc.citation.volume | 22 | en_US |
dc.citation.issue | 6 | en_US |
dc.citation.spage | 453 | en_US |
dc.citation.epage | 464 | en_US |
dc.contributor.department | 分子醫學與生物工程研究所 | zh_TW |
dc.contributor.department | 資訊科學與工程研究所 | zh_TW |
dc.contributor.department | Institute of Molecular Medicine and Bioengineering | en_US |
dc.contributor.department | Institute of Computer Science and Engineering | en_US |
dc.identifier.wosnumber | WOS:000285513400002 | - |
dc.citation.woscount | 2 | - |
顯示於類別: | 期刊論文 |