dc.description.abstractThis study examines the airside performance of heat sinks having fin patterns of plate fin (Type I), interrupted fill geometry (Type II), dense vortex generator (Type III), and loose vortex generator (Type IV). Test results indicate that the heat transfer performance is strongly related to the arrangement of enhancements. The interrupted and dense vortex generator configurations normally contribute more pressure drop penalty than improvements of heat transfer. This is especially pronounced when operated at a lower frontal velocity. Actually the plain fin geometry outperforms most of the enhanced fin patterns such as of Type II and Type Ill at the fully developed region. This is because a close spacing prevents the formation of vortex, and the presence of interrupted surface may also suffer from the degradation by constriction of conduction path. The results suggest that the vortex generators operated at a higher frontal velocity is more beneficial than that of plain fin geometry. In association with the VG-1 criteria (same pumping power and same heat transfer capacity), the results show that effective reduction of surface area can be achieved when the frontal velocities are at 3-5 m s(-1) and the fin patterns are triangular, triangular attack, or two-groups dimple. The result from the present experiment suggests that the asymmetric combination such as using loose vortex generator (Type IV) can be quite effective. The triangular attack vortex generator is regarded as the optimum enhancement design for it could reduce 12-15% surface area at a frontal velocity around 3-5 m s(-1). The asymmetric design is still applicable even when the fin pitch is reduced to 1 mm. (C) 2010 Elsevier Ltd. All rights reserved.en_US
dc.language.isoen_USen_US
dc.subjectHeat sinken_US
dc.subjectInterrupted finen_US
dc.subjectVortex generatoren_US
dc.subjectDimpleen_US
dc.titleAn experimental investigation of air cooling thermal module using various enhancements at low Reynolds number regionen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.ijheatmasstransfer.2010.08.015en_US
dc.identifier.journalINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFERen_US
dc.citation.volume53en_US
dc.citation.issue25-26en_US
dc.citation.spage5675en_US
dc.citation.epage5681en_US
dc.contributor.department機械工程學系zh_TW
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.identifier.wosnumberWOS:000283907700005-
dc.citation.woscount6-
Appears in Collections:Articles


Files in This Item:

  1. 000283907700005.pdf

If it is a zip file, please download the file and unzip it, then open index.html in a browser to view the full text content.