標題: | Differences in PM10 concentrations measured by beta-gauge monitor and hi-vol sampler |
作者: | Chang, CT Tsai, CJ Lee, CT Chang, SY Cheng, MT Chein, HM 環境工程研究所 Institute of Environmental Engineering |
關鍵字: | beta-gauge;water content;PM10;relative humidity |
公開日期: | 1-十一月-2001 |
摘要: | In this paper. differences between the 24-h average PM10 concentrations of Wedding beta -gauge monitor and Andersen or Wedding hi-vol sampler were studied. When the deliquescent point is not exceeded, PM10 concentrations of the beta -gauge are close to those of the manual samplers. The ratio of beta -gauge PM10 to Andersen PM10 and Wedding PM10 is 1.08 +/-0.06 and 1.09 +/-0.12, respectively. However, when the deliquescent point is exceeded, water absorption by the inorganics of aerosols leads to higher PM10 concentrations of the beta -gauge compared to those of the manual sampler. The ratio of beta -gauge PM10 to Andersen PM10 and Wedding PM10 is 1.21 +/-0.22 and 1.27 +/-0.15, respectively. However., due to evaporation of water from the aerosols collected on the filter tape of the beta -gauge, differences in PM10 concentrations are much less than theoretically calculated. (C) 2001 Elsevier Science Ltd. All rights reserved. |
URI: | http://dx.doi.org/10.1016/S1352-2310(01)00369-7 http://hdl.handle.net/11536/29291 |
ISSN: | 1352-2310 |
DOI: | 10.1016/S1352-2310(01)00369-7 |
期刊: | ATMOSPHERIC ENVIRONMENT |
Volume: | 35 |
Issue: | 33 |
起始頁: | 5741 |
結束頁: | 5748 |