完整後設資料紀錄
DC 欄位語言
dc.contributor.authorHu, CNen_US
dc.contributor.authorTzuang, CKCen_US
dc.date.accessioned2014-12-08T15:43:57Z-
dc.date.available2014-12-08T15:43:57Z-
dc.date.issued2001-04-01en_US
dc.identifier.issn0018-9480en_US
dc.identifier.urihttp://dx.doi.org/10.1109/22.915436en_US
dc.identifier.urihttp://hdl.handle.net/11536/29716-
dc.description.abstractThis paper presents the coupled-mode approach to the analysis and design of a large leaky-mode array, in which an N-element microstrip array above a common ground plane supports N coupled leaky modes (leaky EH1 modes) at the first higher order, Following a brief description of a conventional full-wave nonstandard eigenvalue problem for solving the complex propagation constants, we present the detailed formulation of the coupled-mode approach, clearly showing the transformation of the nonstandard eigenvalue problem into a standard one. Thus, all the eigenvalues (complex propagation constants) and eigenvectors (modal current distributions) are solved simultaneously, regardless of the size of the array (N). Two key issues pertinent to the successful implementation of the proposed coupled-mode approach are addressed: the determination of the coupling coefficients and the uniqueness of the isolated uncoupled leaky mode, which represents the leaky modal solution of a single microstrip, but is derived from a system of coupled leaky-mode solutions provided the coupled microstrips have equal width and spacing, Closed-form expressions for obtaining the coupling coefficients of orders two, three, and four are presented. Theoretical studies of closely coupled microstrip arrays of two, three, and four elements show that the magnitude of the coupling coefficient C-i,C-i+j between elements i and i + j decreases at the order of 10(-j). These theoretical case studies also lead to the same isolated uncoupled leaky-mode solution as predicted. Furthermore, the dispersion characteristics of the microstrip array at the first higher order obtained by the coupled-mode approach and the full-wave approach agree excellently for all the case studies, Error analyses indicated that at least two coupling coefficients (C-i,C-i+1 and C-i,C-i+2) are required for obtaining accurate complex propagation constants with rms errors less than 1% for most of the leaky region of the particular array under investigation. An example of applying the proposed coupled-mode approach for analyzing a corporate-fed leaky-mode array of eight elements is reported, revealing that only four out of the eight leaky modes are excited. The coupled-mode theory predicts the far-field radiation pattern in the main beam region in excellent agreement with the measured results.en_US
dc.language.isoen_USen_US
dc.subjectcoupled microstrip linesen_US
dc.subjectcoupled-mode approachen_US
dc.subjectcoupling coefficientsen_US
dc.subjectleaky-mode antennaen_US
dc.subjectleaky modesen_US
dc.titleAnalysis and design of large leaky-mode array employing the coupled-mode approachen_US
dc.typeArticleen_US
dc.identifier.doi10.1109/22.915436en_US
dc.identifier.journalIEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUESen_US
dc.citation.volume49en_US
dc.citation.issue4en_US
dc.citation.spage629en_US
dc.citation.epage636en_US
dc.contributor.department電信工程研究所zh_TW
dc.contributor.departmentInstitute of Communications Engineeringen_US
dc.identifier.wosnumberWOS:000167957000007-
dc.citation.woscount13-
顯示於類別:期刊論文


文件中的檔案:

  1. 000167957000007.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。