標題: Effects of some geometric parameters on the electrostatic precipitator efficiency at different operation indexes
作者: Chang, CL
Bai, HL
環境工程研究所
Institute of Environmental Engineering
公開日期: 1-九月-2000
摘要: The performance of electrostatic precipitators (ESPs) was usually obtained under different geometric parameter values and operation indexes. Hence different conclusions were made in the literature and similar improvements may not be obtained for other applications. In this paper the effects of some geometric parameters on the performance of a wire-plate ESP at different operation indexes are evaluated theoretically. The geometric design parameters include discharge wire diameter, wire-to-wire distance, and plate-to-plate spacing. And the operation indexes considered are the electric field strength, the average current density at plates, and the corona power ratio. The results show that the collection efficiency is increased with a decrease in the wire diameter under the same electric field strength. But opposite results are observed under the same average current density at plates or the same corona power ratio applying to the ESP. The optimal wire-to-wire distance and plate-to-plate spacing vary as the electric field strength is changed. On the other hand, high collection efficiencies are always obtained with decreases in the wire-to-wire distance and the plate-to-plate spacing under the same average current density at plates or the same corona power ratio.
URI: http://dx.doi.org/10.1080/027868200416222
http://hdl.handle.net/11536/30278
ISSN: 0278-6826
DOI: 10.1080/027868200416222
期刊: AEROSOL SCIENCE AND TECHNOLOGY
Volume: 33
Issue: 3
起始頁: 228
結束頁: 238
顯示於類別:期刊論文


文件中的檔案:

  1. 000089099900003.pdf

若為 zip 檔案,請下載檔案解壓縮後,用瀏覽器開啟資料夾中的 index.html 瀏覽全文。