標題: | Magnitude of effect of reaction parameters on 2-chlorophenol decomposition by ultrasonic process |
作者: | Lin, JG Ma, YS 環境工程研究所 Institute of Environmental Engineering |
關鍵字: | ultrasonic-wave energy;o-chlorophenol;hydrogen peroxide;first-order kinetic equation |
公開日期: | 14-May-1999 |
摘要: | In the present work, decomposition of o-chlorophenol (2-cp) was carried out using an ultrasonic process. The extent of 2-cp decomposition depends on several parameters such as ultrasound wave energy (ultrasonic amplitude), addition of hydrogen peroxide (H2O2), pH value (H+ concentration), ionic strength, and initial concentration of 2-cp. The experimental results showed that the decomposition of 2-cp was affected by the various reaction conditions. The profiles of 2-cp decomposition fitted well with the first-order kinetic equation. A linear relationship was obtained between the rate constants of 2-cp decomposition and the varying reaction parameters. The magnitude of effect of reaction parameters such as ultrasonic amplitude, H+ concentration, ionic strength, H2O2 and 2-cp initial concentration on 2-cp decomposition were 0.60, 0,48, 0.19, 0.09 and -0.06, respectively. (C) 1999 Elsevier Science B.V. All rights reserved. |
URI: | http://dx.doi.org/10.1016/S0304-3894(99)00036-9 http://hdl.handle.net/11536/31338 |
ISSN: | 0304-3894 |
DOI: | 10.1016/S0304-3894(99)00036-9 |
期刊: | JOURNAL OF HAZARDOUS MATERIALS |
Volume: | 66 |
Issue: | 3 |
起始頁: | 291 |
結束頁: | 305 |